HEAT operation(230V)
MCFH-GA60VB : MUCFH-GA60VB
HEAT operation(230V)
MCFH-GA50VB : MUCFH-GA50VB
CAPACITY :5.0(kW) INPUT :1890(W)
OUTDOOR WB(
:
)
INDOOR
-10
-5
0
5
10
15
20
DB(
:
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
3.15
1229
3.80
1474
4.45
1663
5.10
1796
5.75
1909
6.35
1966
7.00
2003
21
3.00
1323
3.60
1569
4.25
1739
4.85
1871
5.50
1966
6.10
2022
6.73
2098
26
2.70
1418
3.35
1663
3.95
1833
4.60
1966
5.25
2060
5.85
2117
6.50
2174
CAPACITY :6.8(kW) INPUT :2720(W)
OUTDOOR WB(
:
)
INDOOR
-10
-5
0
5
10
15
20
DB(
:
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
4.28
1768
5.17
2122
6.05
2394
6.94
2584
7.82
2747
8.64
2829
9.52
2883
21
4.08
1904
4.90
2258
5.78
2502
6.60
2693
7.48
2829
8.30
2910
9.15
3019
26
3.67
2040
4.56
2394
5.37
2638
6.26
2829
7.14
2965
7.96
3046
8.84
3128
NOTE
Q :Total capacity (kW)
INPUT:Total power input (W)
DB : Dry-bulb temperature WB : Wet-bulb temperature
PERFORMANCE DATA
HEAT operation(230V)
MCFH-GA35VB : MUCFH-GA35VB
OUTDOOR WB(
:
)
INDOOR
-10
-5
0
5
10
15
20
DB(
:
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
CAPACITY : 3.7(kW) INPUT : 1020(W)
15
21
26
2.33
2.22
2.00
663
714
765
2.81
2.66
2.48
796
847
898
3.29
3.15
2.92
898
938
989
3.77
3.59
3.40
969
1010
1061
4.26
4.07
3.89
1030
1061
1112
4.70
4.51
4.33
1061
1091
1142
5.18
4.98
4.81
1081