8
Specifications and rated conditions of main electric parts
Fuse
(F11)
T3.15AL250V
Horizontal vane motor
(MV)
12 VDC
Varistor
(NR11)
S10K300E2K1 (ERZV10D471)
Terminal block
(TB)
3P
Indoor model
MSZ-SF25VE2
MSZ-SF35VE2
MSZ-SF42VE2
MSZ-SF50VE2
Power supply
Single phase 230 V, 50 Hz
Electrical
data
Power
input 1
Cooling
W
18
22
Heating
24
27
35
Running
current 1
Cooling
A
0.16
0.18
Heating
0.20
0.22
0.27
Fan
motor
Model
RC0J21-AA
Current 1
Cooling
A
0.16
0.18
Heating
0.20
0.22
0.27
Dimensions W × H × D
mm
798 × 299 × 195
Weight
kg
10
Special remarks
Air direction
5
Air
fl ow
Cooling
Super High
m
3
/h
546
594
High
432
474
492
Med.
336
402
420
Low
246
348
372
Silent
192 (210
2)
282 (300
2)
306 (336
2)
Heating
Super High
m
3
/h
618
660
684
720
High
492
498
546
588
Med.
402
432
480
Low
246
348
384
Silent
180 (210 2)
282 (300
2)
306 (336
2)
Sound level
Cooling
Super High
dB(A)
42
45
High
36
38
40
Med.
30
34
36
Low
24
31
33
Silent
19 (21 2)
26 (28 2)
28 (30 2)
Heating
Super High
dB(A)
45
46
47
49
High
39
40
42
43
Med.
34
36
38
Low
24
31
33
Silent
19 (21 2)
26 (28 2)
28 (30 2)
Fan speed
Cooling
Super High
rpm
1,200
1,280
High
1,000
1,070
1,100
Med.
820
940
970
Low
660
850
880
Silent
550 (590 2)
720 (760 2)
770 (820 2)
Heating
Super High
rpm
1,330
1,400
1,500
High
1,100
1,120
1,200
1,270
Med.
940
1,000
1,080
Low
660
850
910
Silent
530 (590 2)
720 (760 2)
770 (820 2)
Fan speed regulator
5
Remote controller model
SG14D
NOTE
: Test conditions are based on ISO 5151.
Cooling: Indoor
Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C
Heating: Indoor
Dry-bulb temperature 20°C Wet-bulb temperature 15°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
1 Measured under rated operating frequency.
2 For multi system.
OBH600E