6
(2) OPERATION
Mode
Condition
Intake air temperature (°F)
DB
WB
Cooling
Standard temperature
80
67
Maximum temperature
90
73
Minimum temperature
67
57
Maximum humidity
78%
Heating
Standard temperature
70
60
Maximum temperature
80
67
Minimum temperature
70
60
3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
Guaranteed voltage (V)
Indoor unit
208/230 V
1 phase
60 Hz
Min. 187
208
230
Max. 253
3-2. OUTLET AIR SPEED AND COVERAGE
● The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed posi-
tion.
The coverage should be used only as a
general guideline since it varies accord-
ing to the size of the room and furniture
arranged inside the room.
Model
Mode
Function
Airflow
(CFM)
Air speed
(ft./s.)
Coverage
(ft.)
MSZ-HM09NA
HEAT
Dry
406
20.6
29.5
COOL
Dry
321
16.3
23.5
Wet
286
14.5
21.0
MSZ-HM12NA
HEAT
Dry
406
20.6
29.5
COOL
Dry
321
16.3
23.5
Wet
286
14.5
21.0
MSZ-HM15NA
HEAT
Dry
463
23.4
33.5
COOL
Dry
420
21.3
30.5
Wet
385
19.5
28.0
MSZ-HM18NA
HEAT
Dry
625
28.5
42.6
COOL
Dry
625
28.5
42.6
Wet
562
25.6
38.4
MSZ-HM24NA
HEAT
Dry
702
32.0
47.7
COOL
Dry
702
32.0
47.7
Wet
632
28.8
43.1
OBH746D