19
8-11. NATURAL FLOW (
) OPERATION
In NATURAL FLOW operation, air
fl
ow will become more like natural wind. An occupant will not be directly exposed to the
air
fl
ow and feel more comfortable.
(1) Press NATURAL FLOW button during COOL or FAN mode to start NATURAL FLOW operation.
(2) Press NATURAL FLOW button again to cancel NATURAL FLOW operation.
• NATURAL FLOW operation is also cancelled when the POWERFUL or ECONO COOL button is pressed.
NOTE:
As the fan speed changes constantly during NATURAL FLOW operation, the sound of air
fl
ow, wind velocity and air
fl
ow
temperature also change. This is not a malfunction.
8-12. SMART SET ( ) OPERATION
1. How to set SMART SET operation
(1) Press OPERATE/STOP (ON/OFF) button.
(2) Select COOL, HEAT or ECONO COOL mode.
(3) Press SMART SET button.
(4) Set the temperature, fan speed, and air
fl
ow direction for SMART SET operation.
NOTE:
• SMART SET operation cannot be selected during DRY or AUTO mode operation.
• The setting range of HEAT mode SMART SET operation is 50°F (10°C) and 61 - 88°F (16 - 31°C).
• 2 groups of setting can be saved. (One for COOL/ECONO COOL, one for HEAT)
• SMART SET operation and the weekly timer operation cannot be used together.
2. How to cancel operation
• Press SMART SET button again.
• SMART SET operation can also be cancelled by pressing OPERATION SELECT button to change the operation mode.
The same setting is select from the next time by simply pressing SMART SET button.
8-13. EMERGENCY/TEST OPERATION
In the case of test run operation or emergency operation, use
EMERGENCY OPERATION switch on the right side of the indoor unit.
Emergency operation is available when the remote controller is missing
or has failed, or when the batteries in the remote controller are running
down. The unit will start and OPERATION INDICATOR lamp will light up.
The first 30 minutes of operation is the test run operation. This opera-
tion is for servicing. The indoor fan runs at High speed and the tem-
perature control does not work.
After 30 minutes of test run operation, the system shifts to
EMERGENCY COOL/HEAT MODE with a set temperature of 75°F (24°C).
The fan speed shifts to Medium.
The coil frost prevention works even in the test run or the emergency
operation.
In the test run or emergency operation, the horizontal vane operates in
VANE AUTO ( ) mode.
Emergency operation continues until EMERGENCY OPERATION
switch is pressed once or twice or the unit receives any signal from the
remote controller. In the latter case, normal operation will start.
NOTE:
Do not press EMERGENCY OPERATION switch during normal
operation.
Operation mode
COOL/HEAT
Set temperature
75°F (24°C)
Fan speed
Med.
Horizontal vane
Auto
The operation mode is indicated by the Operation
Indicator lamp as following
Operation Indicator lamp
EMERGENCY COOL
↓
EMERGENCY HEAT
↓
STOP
Lighted
Not
lighted
8-14. 3-MINUTE TIME DELAY OPERATION
When the system turns OFF, compressor will not restart for 3 minutes as 3-minute time delay function operates to protect
compressor from overload.
Emergency
operation switch
(E.O. SW)
OBH683B