En-4

 AUTO mode (Auto change over)

The unit selects the operation mode according to the difference between the 

room temperature and the set temperature. During AUTO mode, the unit 

changes mode (COOL↔HEAT) when the room temperature is 2°C away 

from the set temperature for more than 15 minutes.

Note: 

Auto Mode is not recommended if this indoor unit is connected to a MXZ 

type outdoor unit. When several indoor units are operated simultaneously, 

the unit may not be able to switch operation mode between COOL and 

HEAT. In this case, the indoor unit becomes standby mode (Refer to table 

of Operation indicator lamp).

 COOL mode

Enjoy cool air at your desired temperature. 

Note: 

Do not operate COOL mode at very low outside temperatures (less than 

-10°C). Water condensed in the unit may drip and wet or damage furni-

ture, etc.

  DRY mode

Dehumidify your room. The room may be cooled slightly. 

Temperature cannot be set during DRY mode.

 HEAT mode

Enjoy warm air at your desired temperature.

  FAN mode

Circulate the air in your room.

Operation indicator lamp

Emergency operation

When the remote controller cannot be used...

Emergency operation can be activated by pressing the emergency operation 

switch (E.O.SW) on the indoor unit.

Each time the E.O.SW is pressed, the operation changes in 

the following order:

1

Press 

 to start the operation.

2

Press 

 to select operation mode. Each press 

changes mode in the following order:

3

Press 

 or 

 to set the temperature.

Each press raises or lowers the temperature by 1°C.

 

Press 

 to stop the operation.

Auto restart function

If a power failure occurs or the main power is turned off during operation, “Auto 

restart function” automatically starts operation in the same mode as the one 

set with the remote controller just before the shutoff of the main power. When 

timer is set, timer setting is cancelled and the unit starts operation when power 

is resumed.

If you do not want to use this function, please consult the service repre-

sentative because the setting of the unit needs to be changed.

S

ELECTING OPERATION MODES

Set temperature : 24°C

Fan speed : Medium

Horizontal vane : Auto

Emergency COOL

Emergency HEAT

Stop

Note:

•  The fi rst 30 minutes of operation is test run. Temperature 

control does not work, and fan speed is set to High.

•  In the emergency heating operation, the fan speed gradu-

ally rises to blow out warm air.

•  In the emergency cooling operation, the horizontal vanes’ 

position will be reset in about a minute, then the operation 

will start.

 (AUTO)  (COOL) 

(DRY) 

(HEAT) 

(FAN)

Note:

Multi system operation

Two or more indoor units can be operated by one outdoor unit. When several 

indoor units are operated simultaneously, cooling/fan and heating operations 

cannot be done at the same time. When COOL/FAN is selected with one unit 

and HEAT with another or vice versa, the unit selected last goes into standby 

mode.

Operation indicator lamp

The operation indicator lamp shows the operation state of the unit.

Indication

Operation state

Room temperature

The unit is operating to reach the set 

temperature

About 2°C or more  

away from set tem-

perature

The room temperature is approach-

ing the set temperature

About 1 to 2°C from 

set temperature

Standby  mode  (only  during  multi 

system operation)

  Lighted 

  Blinking 

  Not lighted

SG79F596H01_en.indd   4

2011/03/15   7:56:12

Summary of Contents for MSZ-EF22VAB

Page 1: ...MSZ EF42VAW MSZ EF50VAW MSZ EF22VAB MSZ EF25VAB MSZ EF35VAB MSZ EF42VAB MSZ EF50VAB MSZ EF22VAS MSZ EF25VAS MSZ EF35VAS MSZ EF42VAS MSZ EF50VAS English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating in structions before use ...

Page 2: ...ct handling could cause serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal condition such as a burning smell sto...

Page 3: ...unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor con tribute to growth of fungi such as mold or clog the drain pas sage and cause water to leak from the indoor unit Consult your dealer for inspection and maintenance which require sp...

Page 4: ...s either the TIME button or the TIMER buttons to set the time Each press increases decreases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Remote controller holder Signal transmitting section Distance of signal About 6 m Beep s is are heard from the indoor unit when the signal is received Operation display section ON OFF operate stop button Temperature b...

Page 5: ...on Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is cancelled and the unit starts operation when power is resumed If you do not want to use this function please co...

Page 6: ...ir flow Moving the horizontal vanes with your hands causes them to mal function When the breaker is turned on the horizontal vanes position will be reset in about a minute then the operation will start The same is true in the emergency cooling operation When the horizontal vanes seem to be in an abnormal position see page 9 AUTO Quiet Low Med High Super High AUTO 1 2 3 4 5 SWING Airflow direction ...

Page 7: ...h a single push of the button Note When using the multi system MXZ 8A140 the temperature cannot be set to 10 C Even if the temperature is set to 10 C the air conditioner will operate at 16 C ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycles according to the temperature airflow Press again to cancel ECONO ...

Page 8: ...o turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer setting 1 Press to enter the weekly timer setting mode blinks 2 Press or to view the setting of the particular day or number Press to exit the weekly timer setting Note When all days of the week are selected to view the settings and a different set ting is incl...

Page 9: ...aner When dirt cannot be removed by vacuum cleaning Soak the filter and its frame in lukewarm water before rinsing it After washing dry it well in shade Install all tabs of the air filter Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 2320FT Pull to remove from the air filter What is Nano platinum filter Nano platinum is a ceramic particle that includes a pla...

Page 10: ...unning Even if the fan starts to rotate it stops soon When the outside temperature is low during cooling operation the fan operates intermittently to maintain sufficient cooling capacity Water leaks from the outdoor unit During COOL and DRY operations pipe or pipe connecting sections are cooled and this causes water to condense In the heating operation water condensed on the heat exchanger drips do...

Page 11: ... the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit Moisture in the air conditioner contributes to favorable conditions for growth of fungi such a...

Page 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79F596H01 ...

Reviews: