background image

SPLIT-TYPE AIR CONDITIONERS

INDOOR UNIT

MSY-GW25VFD MSY-GW35VFD MSY-GW42VFD
MSY-GW50VFD MSY-GW60VFD MSY-GW71VFD MSY-GW80VFD

English

OPERATING INSTRUCTIONS

 

For user

•  To use this unit correctly and safely, be sure to read these operating  

instructions before use.

DG79A01WH01_Cover.indd   1

2022/02/11   10:44:41

Summary of Contents for MSY-GW25VFD

Page 1: ...D MSY GW35VFD MSY GW42VFD MSY GW50VFD MSY GW60VFD MSY GW71VFD MSY GW80VFD English OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read these operating instructions before use DG79A01WH01_Cover indd 1 2022 02 11 10 44 41 ...

Page 2: ...ause fire After the indoor unit is switched OFF with the remote controller make sure to turn the breaker OFF or disconnect the power plug Do not expose your body directly to cool air for a prolonged length of time This could be detrimental to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electr...

Page 3: ...ition Immediately stop operating the air conditioner and consult your dealer Replace all batteries of the remote controller with new ones of the same type Using an old battery together with a new one may cause overheat ing leakage or explosion If the battery fluid comes in contact with your skin or clothes wash them thoroughly with clean water If the battery fluid comes in contact with your eyes was...

Page 4: ...e Air outlet Air filter Nano platinum filter Air inlet Heat exchanger Front panel Air cleaning filter Anti Allergy Enzyme Filter option Display section GW50 60 GW25 35 42 Operation indicator lamp Remote control receiving section Air cleaning filter Anti Allergy Enzyme filter option Air inlet Air filter Nano platinum filter Front panel Air outlet Heat exchanger Emergency operation switch Page 10 Horizonta...

Page 5: ... Each press increases de creases the time by 1 minute 10 minutes when pressed longer 3 Press the DAY button to set the day Note Press CLOCK gently using a thin instrument Note Make sure the polarity of the batteries is correct Do not use manganese batteries and leaking batteries The remote controller could malfunction Do not use rechargeable batteries The battery replacement indicator lights up wh...

Page 6: ...L operation the set temperature may not be changed when the room temperature is more than 2 C higher than the set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature COOL mode Enjoy cool air at your desired temperature DRY mode Dehumidify your room The room may be cooled slightly Temperature cannot be set during DRY mode FAN mode Circulate the...

Page 7: ... direction in the following order GW71 80 1 Press to select horizontal airflow direction Each press changes airflow direction in the following order SWING SWING Up down Airflow direction 1 Press to select airflow direction Each press changes airflow direction in the following order Two short beeps are heard from the indoor unit when set to AUTO AUTO 1 2 3 4 5 SWING AUTO The vane is set to the most eff...

Page 8: ...ERATION 1 Press to start LONG operation Fan speed increases and the horizontal vane moves to the position for LONG mode Air reaches to longer distance Press again to cancel LONG operation LONG operation is cancelled when the OFF ON VANE or ECONO COOL button is pressed 1 Press during COOL mode page 5 to start POWERFUL operation Fan speed Exclusive speed for POWERFUL mode Horizontal vane Set positio...

Page 9: ... correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Set the timer while or is blinking Press or again to cancel timer Note ON and OFF timers can be set together mark indicates the order of timer operations If power failure occurs while ON OFF timer is set see page 10 AUTO RE START FUNCTION TIMER OPERATION ON OFF TIME...

Page 10: ...s and hold for 5 seconds to erase all weekly timer settings Point the remote controller toward the indoor unit 5 Press to turn the weekly timer ON lights When the weekly timer is ON the day of the week whose timer setting is complete will light Press again to turn the weekly timer OFF goes out Note The saved settings will not be cleared when the weekly timer is turned OFF Checking weekly timer set...

Page 11: ...is not more than 75 of the total electrical energy that would be con sumed if operating at the rated capacity in a half hour period Note DRM is automatically activated or released according to the signals from DRED DRM cannot be invalidated or changed manually You might feel this unit does not sufficiently perform cooling operation during DRM Operation settings can be changed as usual with the remo...

Page 12: ...manent antibacterial and deodorizing characteristics for the filter Nano plati num surpasses the catechin a bioflavonoid that is found in green tea in perfor mance Nano platinum filter uses this compound not only to improve air quality but also to eliminate bacteria and viruses This air filter has a semi permanent lasting effect even after washing it with water Important Clean the filters regularly for...

Page 13: ...propriate Please change fan speed to High or Super High Page 6 Are the filters clean Page 11 Is the fan or heat exchanger of the indoor unit clean Page 11 Are there any obstacles blocking the air inlet or outlet of the indoor or outdoor unit Is a window or door open When a ventilation fan or a gas cooker is used in a room the cooling load increases resulting in an insufficient cooling effect When th...

Page 14: ...he highest temperature set or FAN mode for 3 to 4 hours Page 5 This dries the inside of the unit Moisture in the air conditioner contributes to growth of fungi such as mold 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power sup ply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 11 2 Check that the...

Page 15: ......

Page 16: ...HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN DG79A01WH01 DG79A01WH01_Cover indd 2 2022 02 11 10 44 41 ...