21
21
How to check mis-wiring
D
During EMERGENCY OPERATION, is there
10 V DC between both ends of R601 on the
deicer P.C. board?
(By tester, the stylus is between 5 ~10 V.)
Refer to outdoor unit service manual.
Start
No
No
Is there 20 V DC between both ends of
R132 on the indoor electronic control P.C.
board ?
( By tester, the stylus is between 0 ~ 20 V. )
• Turn ON the power supply. (indoor/outdoor unit)
• Press EMERGENCY OPERATION switch once.
Is this mis-wiring, poor contact,
or wire disconnection?
Correct them.
Replace the indoor electronic
control P.C. board.
Is there 230 V AC between
L
-
N
on the outdoor terminal block?
No
Check the outdoor power supply
and connection of wiring.
Yes
No
Replace the deicer P.C. board.
Yes
No
Make the wiring between CN730
on the deicer P.C. board and
outdoor terminal block correct.
Replace the deicer P.C. board.
Yes
Is there 5 V DC between J101 + -J401 -
on the deicer P.C. board?
Yes
Yes
After 3 minutes, mis-wiring is indicated
(0.5-second ON, 0.5-second OFF)
on OPERATION INDICATOR
lamp on indoor unit.
Short circuit of JPG and JPS on the indoor electronic control
P.C. board enables self -check to be displayed in 3 seconds.
• Turn OFF the power supply. (indoor unit)
• Connect indoor/outdoor connecting
wire.
Turn ON the power supply. (outdoor unit)
1. Turn OFF the power supply (indoor/outdoor unit) and disconnect indoor and outdoor
connecting wire on indoor side.
2. Short-circuit terminal block
N
-
3
by lead wire.
3. Turn ON the power supply (indoor unit) and press EMERGENCY OPERATION switch once.
When OPERATION INDICATOR lamp flashes ON and OFF in every 0.5-second.
Outdoor unit does not operate.
OBH513A
Summary of Contents for MSH-GD80VB-E1