![Mitsubishi Electric MSH-18RV Operating Instructions Manual Download Page 17](http://html.mh-extra.com/html/mitsubishi-electric/msh-18rv/msh-18rv_operating-instructions-manual_1810448017.webp)
17
SPECIFICATIONS
Model
Function
Power supply
Capacity
kW
Input
kW
Weight
Indoor
kg
Outdoor
kg
Refrigerant filling
kg
capacity (R-22)
IP code
Indoor
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Noise level
Indoor
dB(A)
(Hi)
Outdoor
dB(A)
MSH-18RV
MSH-24RV
Cooling
Heating
Cooling
Heating
~ /N, 220-240V, 50Hz
5.1
5.4
6.0
6.2
2.03-2.12
1.98-2.07
2.72-2.75
2.47-2.58
14
54
72
1.65
2.40
IP20
IP24
1.3
4.5
4.2
42
45
52
53
Model
Function
Power supply
Capacity
kW
Input
kW
Weight
Indoor
kg
Outdoor
kg
Refrigerant filling
kg
capacity (R-407C)
IP code
Indoor
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Noise level
Indoor
dB(A)
(Hi)
Outdoor
dB(A)
MSH-C18TV
MSH-C24TV
Cooling
Heating
Cooling
Heating
~ /N, 230V, 50Hz
5.2
6.0
6.3
7.5
2.11
2.18
2.85
3.02
14
54
71
1.60
2.00
IP20
IP24
1.7
5.0
42
45
52
53
Note:
1. Rating condition
Cooling — Indoor:
27
°
C DB, 19
°
C WB
Outdoor: 35
°
C DB
Heating — Indoor:
20
°
C DB
Outdoor: 7
°
C DB, 6
°
C WB
2. Guaranteed operating range
Indoor
Outdoor
Upper limit
32
°
C DB
43
°
C DB
Cooling
23
°
C WB
—
Lower limit
21
°
C DB
21
°
C DB
15
°
C WB
—
Upper limit
27
°
C DB
21
°
C DB
Heating
—
15
°
C WB
Lower limit
20
°
C DB
-8.5
°
C DB
—
-9.5
°
C WB