ON/OFF

FAN

TOO

WARM

TOO

COOL

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

AM

PM

CLOCK

˚C

AMPM

HEAT

RESET CLOCK

AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT

AIR FLOW velocity and direction can be selected
as required.

To change the AIR FLOW velocity, press
the 

FAN

 button.

Each time the button is pressed, the fan speed is
changed in sequence:   (Lo) 

 

 (Med) 

 

 (Hi) 

 (AUTO)

Use the 

 (Hi) notch to cool/heat the room more.

If the operating sound of the air conditioner disturbs your
sleep, use the   (Lo) notch.

To change the AIR FLOW blowing direc-
tion vertically, press the 

VANE

 button.

Each time the button is pressed, the angle of the hori-
zontal vane is changed in sequence: 

(1) 

 

(2)

 

(3) 

 

(4) 

 (5) 

   (SWING) 

 

 (AUTO)

SWING OPERATION

Use the swing operation for the air flow to reach all corners
of the room.

Recommended horizontal vane
range

Use the  

  (AUTO) position usu-

ally.
Use position 

(1) or 

(2) in the

COOL or DRY mode and use posi-
tions 

(3) to

 (5) in the HEAT

mode when adjusting to your re-
quirements.

NOTE

In the cooling operation, when the air conditioner is op-
erated with setting the horizontal vane to

 (4) or

 (5)

for 1 hour, the AIR FLOW direction is automatically set
to horizontal to prevent condensed water from dropping.

Adjust the vertical AIR FLOW direction using the remote
controller. If the horizontal vane is moved manually, it
may cause trouble.

In the heating operation, if the air flow temperature is
too low or when defrosting is being done, the horizontal
vane position is set to 

(1).

Auto air flow direction control operation

When the AUTO mode is selected with the 

VANE

 button, the position of the horizontal vane is automatically set

to correspond to the operation mode for effective operation.

(1) HEAT

When the air flow temperature is too low,

When the air flow temperature rises,

the air is blown out horizontally.

the air is blown out downwards.

(2) COOL, DRY

The air is blown out horizontally.

To change the horizontal direction of the air flow, move the vertical vane manu-
ally.

Adjust the vane before operation starts.
Since the horizontal vane moves automatically, your fingers may be caught.

COOL

DRY

HEAT

1

2

3

4

5

Summary of Contents for MSH-18RV

Page 1: ... aparato y por razones de seguridad debe leer este manual de instrucciones de manejo antes de su utilización LIBRETTO D ISTRUZIONI Per gli utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPE...

Page 2: ... shock be careful Blue Be sure to disconnect the power supply plug from the power outlet Blue Be sure to shut off the power After reading this manual keep it together with the installation manual in a handy place for easy reference Warning mark positions and safety devices FRONT PANEL ENCLOSURE ENCLOSURE AIR OUTLET SAFETY PRECAUTIONS 2 NAME OF EACH PART 5 PREPARATION BEFORE OPERATION 7 I FEEL AUTO...

Page 3: ...not use an insecti cide or flammable spray This may cause a fire or defor mation of the cabinet Ventilate well in using the unit with a stove etc An oxygen shortage may occur Do not use the unit for special purposes Do not use this air conditioner to preserve precision devices food animals plants and art ob jects This may cause deterioration of quality etc Do not put a stove etc where they are exp...

Page 4: ...type Using an old battery together with a new one may result in heat generation leakage or an explo sion Do not charge or disas semble the batteries and do not throw them into a fire This may result in leakage fire or an explosion If liquid from the alkaline batteries gets onto your skin or clothes wash it well with clean water If liquid from the alkaline batter ies gets into your eyes wash them w...

Page 5: ...l receiving section Horizontal vane Remote controller Display section Emergency operation switch Operation Indicator lamp Receiving section Deodorizing filter Gray sponge type OPTION Air cleaning filter White bellows type OPTION Air inlet back and side Piping Drainage hose Air outlet Drain outlet MUH 18RV MUH C18TV MUH 24RV MUH C24TV Air inlet back and side Piping Drainage hose Air outlet Drain ou...

Page 6: ...PM TOO WARM Signal transmitting section Operation display section ON OFF operate stop button Operation select button Fan speed control button ECONO COOL button On timer button CLOCK set button HR button MIN button Time set button Temperature buttons Vane control button Off timer button RESET button This diagram shows an overall view NAME OF EACH PART Remote controller ...

Page 7: ...Y OPERA TION switch is once pressed the unit will oper ate in test run for 30 minutes and then the op eration mode shifts to EMERGENCY MODE Details of EMERGENCY MODE are as shown below However the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation The fan speed is set to Hi in test run and shifts to Medium after 30 minutes Operation mode COOL H...

Page 8: ...n mode by pressing the MODE button Details of auto operation NOTE COOL When the room temperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room ...

Page 9: ...m gen erally available on the window Heat entering the room is re duced 3 Block the outdoor unit from di rect sunlight This saves en ergy HEAT Comfortable warmth depends on the temperature difference between the indoor and the outdoor It is recommended that the set temperature in the heating operation does not differ from the external tem perature too much Though there is a regional difference as ...

Page 10: ...o your re quirements NOTE In the cooling operation when the air conditioner is op erated with setting the horizontal vane to 4 or 5 for 1 hour the AIR FLOW direction is automatically set to horizontal to prevent condensed water from dropping Adjust the vertical AIR FLOW direction using the remote controller If the horizontal vane is moved manually it may cause trouble In the heating operation if t...

Page 11: ...ner Also SET TEMPERATURE is automatically set 2 C higher than in COOL mode To release the ECONO COOL operation Press the ECONO COOL button again ECONO COOL operation is available only in MANUAL COOL mode When the VANE button is pressed or the operation mode is changed during the ECONO COOL operation ECONO COOL operation is released The FAN button the TOO WARM or TOO COOL button and ON OFF timer pa...

Page 12: ...st will operate first mark indicates the order of timer operations If the current time has not been set the timer operation can not be used WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME When it is not going to be used for a long time 1 Perform the FAN operation for 3 or 4 hours to dry the inside of the air conditioner To perform FAN operation set to the highest temperature in th...

Page 13: ...t is conspicuous use a solution of detergent in lukewarm water If hot water 50 C or more is used the filter may be deformed Do not use a scrubbing brush or sponge This may damage the surface of the filter Do not use a chlorine detergent 3 After washing with water lukewarm water dry the deodorizing filter well in the shade Do not expose the deodorizing filter to direct sunlight or heat from a fire ...

Page 14: ...parts Optional parts are available from your local dealer Name of part Type name DEODORIZING FILTER MAC 1600DF AIR CLEANING FILTER MAC 1100FT The air conditioner cannot be operated d d d d d Check the following 1 Is the breaker turned on 2 Isn t the fuse blown Cannot be cooled or heated sufficiently d d d d d Check the following 1 Is the temperature set ting correct 2 Isn t the filter dirty 3 Isn ...

Page 15: ...the outside wind is strong When a ventilation fan or a gas cooker is used in a room the cooling load increases resulting in an in sufficient cooling effect When the outside air temperature is high the cooling effect may not be sufficient Answer not a malfunction This is the switching sound in turning on off the fan or the compressor When the air conditioner is operated in COOL or DRY mode if the o...

Page 16: ...and collect around the unit it may cause an explosion Where there is much machine oil Salty places such as the seaside Where sulfide gas is generated such as a hot spring Where oil is splashed or where the area is filled with oily smoke Electrical work Provide an exclusive circuit for the power supply of the air conditioner Be sure to observe the breaker capacity WARNING The customer should not in...

Page 17: ... Input kW Weight Indoor kg Outdoor kg Refrigerant filling kg capacity R 407C IP code Indoor Outdoor Permissible LP ps MPa excessive operating HP ps MPa pressure Noise level Indoor dB A Hi Outdoor dB A MSH C18TV MSH C24TV Cooling Heating Cooling Heating N 230V 50Hz 5 2 6 0 6 3 7 5 2 11 2 18 2 85 3 02 14 54 71 1 60 2 00 IP20 IP24 1 7 5 0 42 45 52 53 Note 1 Rating condition Cooling Indoor 27 C DB 19 ...