MICROPROCESSOR CONTROL
8
Once the operation mode are set, the same operation mode
can be repeated by simply turning the OPERATE/STOP
(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
8-1. “I FEEL CONTROL” (
) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button on the remote
controller. Operation Indicator lamp of the indoor unit
turns on with a beep tone.
(2) Press OPERATION SELECT button to set “I FEEL
CONTROL”(
). Then a beep tone is heard.
(3) The operation mode is determined by the room
temperature at start-up of the operation.
lighting
not lighting
Approx. 2
:
or more
Difference
betweeen set
temperature
and room
temperature
Approx. 2
:
or less
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait unit the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
Operation state
Indication
Operation Indicator
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
INDOOR UNIT DISPLAY SECTION
WIRELESS REMOTE CONTROLLER
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
• Once the mode is fixed, the mode does not change by
room temperature afterwards.
• Under the ON-TIMER (
) operation, mode is
determined according to the room temperature as the
operation starts.
• When the system is stopped with the OPERATE/STOP
(ON/OFF) button on the remote controller, and restarted
within 2 hours in “I FEEL CONTROL” (
) mode, the
system operates in previous mode automatically
regardless of the room temperature.
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperature
25
:
or more
23
:
to 25
:
less than 23
:
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours and more, the
operation mode is determined by the room temperature
at start-up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY or
HEAT mode of “I FEEL
CONTROL” that
determined by room
temperature at start-up
of the operation.
MSH-18NV -
E4