WARNING
•
Use the indoor/outdoor unit connecting wire that meets the Standards to connect
the indoor and outdoor units and fix the wire to the terminal block securely so that
no external force is conveyed to the connecting section of the terminal block.
Incomplete connection or fixing of the wire could result in a fire.
•
Attach the electrical cover securely. If it is attached incorrectly, it could result in a
fire or an electric shock due to dust, water, etc.
AIR INTAKE
GRILLE
ELECTRICAL COVER
Fixing screws
Indoor and outdoor connecting wire
A
CAUTION
•
Be careful not to make mis-wiring.
•
Firmly tighten the terminal screws to prevent them from loosening.
•
After tightening, pull the wires lightly to confirm that they do not move.
•
If the connecting wire is incorrectly connected to the terminal block, the unit does
not operate normally.
•
If a ground is incorrect, it may cause an electric shock.
4-4 AUTO RESTART FUNCTION
•
When the units of these models are shipped from the factory, auto restart function is
set to ON. If you want to know how to release this function, consult the service
center.
•
When the indoor unit is controlled with the remote controller, the operation mode, the
set temperature, and the fan speed are memorized by the indoor electronic control
P.C. board. The auto restart function sets to work the moment the power has restored
after power failure, then, the unit will restart automatically. If the unit is operated in
“I FEEL CONTROL” mode before power failure, the operation is not memorized. In
“I FEEL CONTROL” mode, the operation is decided by the initial room temperature at
(re)start.
Operation
1
If the power of the indoor unit (115V AC) has been cut, the operation settings
remain.
Remark:
When indoor and outdoor unit are powered in separate circuit even if the power of the
outdoor unit (208/230V AC) is cut auto restart function doesn’t work.
2
When three minutes have passed after power was restored, the unit will restart
automatically according to the memory.
Notes:
•
The operation settings are memorized when 10 seconds have passed after the
remote controller was operated.
•
If the main power is turned off or a power failure occurs while AUTO START/STOP
timer is active, the timer setting is cancelled. As these models are equipped with the
auto restart function, the air conditioner should start operating at the same time that a
power has restored.
•
If the unit has been off with the remote controller before power failure, the auto
restart function does not work as the power button of the remote controller is off.
•
To prevent breaker off due to the rush of starting current, systematize other home
appliances not to turn on at the same time.
4-5 PIPE FORMING
•
Place the drain hose below the refrigerant piping.
•
Make sure that the drain hose is not heaved or snaked.
•
Do not pull the hose to apply the tape.
•
When the drain hose passes the room, be sure to wrap insulation material (obtain-
able at a store) around it.
•
Wrap the felt tape
7
around the pipe and the drain hose, then put the pipe in the
back space of the indoor unit.
Be careful drain hose is not
heaved.
Cut off in case of right piping.
Cut off in case of downward piping.
FOR REAR, RIGHT OR DOWNWARD PIPING
•
Pipe arrangement
Put the refrigerant piping and the drain hose together, then apply piping tape
G
to
them.
•
Insert the piping and the drain hose into the wall hole sleeve
C
, and hook the upper
part of the indoor unit on the installation plate
1
.
•
Check if the indoor unit is hooked securely on the installation plate
1
by moving the
unit to left and right.
•
Thrust the lower part of the indoor unit into the installation plate
1
.
Drain hose
Liquid pipe
Gas pipe
Felt tape
7
Firmly apply piping tape
G
from the end.
MS12/15/17TN
Loosen terminal screw.
Lead wire
Terminal block
Grounding
terminal
INDOOR UNIT
Terminal block
Disconnect switch
∗∗
115V AC
∗
1phase, 60Hz
DC12 V
(Polar)
Terminal block 2
OUTDOOR UNIT
Terminal
block 1
Ground
Power supply
208/230V AC, 1phase 3wires, 60Hz
Grounding
terminal
<Connection details>
MSH12/15TN
Grounding
terminal
INDOOR UNIT
Terminal block
Disconnect switch
∗∗
115V AC
∗
1phase, 60Hz
DC12 V
(Polar)
Terminal block 2
OUTDOOR UNIT
Terminal
block 1
Ground
Power supply
208/230V AC, 1phase 3wires, 60Hz
Grounding
terminal
Connect wires to the matching numbers
of terminals.
Remark:
∗
Indoor unit can also be
powered from an
independent power supply
[Max. Fuse size (time
delay) : 15 A].
In this case these indoor/
outdoor connecting wires
for indoor power supply
are not necessary.
∗∗
A disconnect switch may
be required.
Check the local code.
Remark:
∗
Indoor unit can also be
powered from an
independent power supply
[Max. Fuse size (time
delay) : 15 A].
In this case these indoor/
outdoor connecting wires
for indoor power supply
are not necessary.
∗∗
A disconnect switch may
be required.
Check the local code.
CONNECTING WIRES
•
Wire to be AWG22 double insulated, 300 V insulation. Equal to Belden 9407
(for 12 V DC).
•
Use copper conductors only.