10
WIRELESS REMOTE CONTROLLER
MICROPROCESSOR CONTROL
9
NOTE
: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receives the signal of the
remote controller with beeps.
Signal transmitting section
Operation display section
Temperature buttons
OPERATE/STOP
(ON/OFF) button
Indication of
remote controller
model is on back
TIME SET buttons
FORWARD button
BACKWARD button
VANE CONTROL button
OFF-TIMER button
RESET button
FAN SPEED CONTROL button
OPERATION SELECT button
ECONO COOL button
ON-TIMER button
CLOCK button
POWERFUL COOL button
MS-GF20VA MS-GF25VA MS-GF35VA
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
The unit is operating to
reach the set temperature
About 2°C or more away
from set temperature
The room temperature is
approaching the set tem-
perature
About 1 to 2°C from set
temperature
INDOOR UNIT DISPLAY SECTION
Lighted
Blinking
Not lighted
9-1. COOL ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button) to select the desired temperature. The setting range
is 16 - 31°C.
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.