background image

FOR LEFT OR LEFT-REAR PIPING

 Pipe arrangement

  Put the refrigerant piping and the drain hose together, then apply felt tape 

7

 to 

them.

FOR REAR, RIGHT OR DOWNWARD PIPING

 Pipe arrangement

 

Put the refrigerant piping and the drain hose together, then apply piping tape 

G

 to 

them.

4-5  AUTO RESTART FUNCTION

  These models are equipped with an auto restart function. If you do not want to use 

this function, please consult the service representative because the setting of the 
unit needs to be changed.

  When the indoor unit is controlled with the remote controller, the operation mode, 

the set temperature, and the fan speed are memorized by the indoor electronic 
control P.C. board. The auto restart function sets to work the moment the power 
has restored after power failure, then, the unit will restart automatically. If the unit is 
operated in 
“I FEEL...” or “AUTO” mode before power failure, the operation mode (COOL, DRY 
or HEAT) is not stored in the memory. When the main power is turned on, the unit 
decides the operation mode by the initial room temperature at restart and starts 
operation again.

Operation

1

  If the main power (230V AC) has been cut, the operation settings remain.

2

  When three minutes have passed after power was restored, the unit will restart 

automatically according to the memory.

Notes:

  The operation settings are memorized when 10 seconds have passed after the 

remote controller was operated.

  If the main power is turned off or a power failure occurs while AUTO START/STOP 

timer is active, the timer setting is cancelled. As these models are equipped with an 
auto restart function, the air conditioner starts operating with timer cancelled at the 
same time that power is restored.

  If the unit has been off with the remote controller before power failure, the auto 

restart function does not work as the power button of the remote controller is off.

  To prevent breaker off due to the rush of starting current, systematize other home 

appliances not to turn on at the same time.

4-6 PIPE FORMING

  Place the drain hose below the refrigerant piping.

  Make sure that the drain hose is not heaved or snaked.

  Do not pull the hose to apply the tape.

  When the drain hose passes the room, be sure to wrap insulation material 

(obtainable at a store) around it.

  Wrap the felt tape 

7

 around the pipe and the drain hose, then put the pipe in the 

back space of the indoor unit.

Drain hose

Drain cap

Cut off in case of left piping.

Felt tape 

7

Firmly apply felt tape 

7

 from the end.

(Felt tape 

7

 overlap width should be 1/3 

the tape width.)

Use a bandage stopper at 
the end of felt tape 

7

.

Drain cap

CAUTION

O

  Be careful not to make mis-wiring.

O

  Firmly tighten the terminal screws to prevent them from loosening.

O

  After tightening, pull the wires lightly to confi rm that they do not move.

O

  If the connecting wire is incorrectly connected to the terminal block, the unit does 

not operate normally.

O

  If an earth is incorrect, it may cause an electric shock.

Liquid pipe

Gas pipe

Felt tape 

7

Indoor/outdoor unit 
connecting wire 

A

  3  Put the drain cap into the section to which the drain hose is to be 

attached at the rear of the indoor unit.

Insert the screwdriver, etc. (not sharp-edged tool) into the hole at the end of the cap and 
insert the cap fully into the drain pan.

2  Pull out the drain hose at the rear left of the indoor unit.

Hold the claw marked by the arrow and pull out the drain hose forward.

1  Pull out the drain cap at the rear right of the indoor unit.

Hold the convex section at the end and pull the drain cap.

REATTACHING DRAIN HOSE

Be sure to reattach the drain hose and the drain cap in case of left or left-rear piping.
Otherwise, it could cause drops of water to drip down from the drain hose.

Cut off in case of right piping.

Firmly apply piping tape 

G

from the end.

Cut off in case of downward piping.

Be careful drain hose is not 
heaved.

  Insert the piping and the drain hose into the wall hole sleeve 

C

, and hook the upper 

part of the indoor unit on the installation plate 

1

.

  Check if the indoor unit is hooked securely on the installation plate 

1

 by moving the 

unit to left and right.

  Thrust the lower part of the indoor unit into the installation plate 

1

.

Be careful drain 
hose is not heaved.

Drain cap

Summary of Contents for MS-GA60VB

Page 1: ...inflammable gas leaks If gas leaks and accumulates in the area surrounding the unit it could cause an explosion Q Install an earth leakage breaker depending on the installation place Where it is humid If an earth leakage breaker is not installed it could cause an electric shock Q Perform the drainage piping work securely according to the installation manual If there is a defect in the drainage pipi...

Page 2: ...nstallation Indoor unit 1 Installation plate 1 2 Installation plate fixing screw 4 25 mm 7 3 Remote controller holder 1 4 Fixing screw for 3 3 5 16 mm Black 2 5 Battery AAA for remote controller 2 6 Wireless remote controller 1 7 Felt tape Used for left or left rear piping 1 8 Air cleaning filter 2 PART TO BE PROVIDED AT YOUR SITE Optional extension pipe A Indoor outdoor unit connecting wire 2 core ...

Page 3: ...ioning of the holes on the wall 4 2 WALL HOLE DRILLING 1 Determine the wall hole position 2 Drill a 75 mm hole so that outside can be lower than inside 3 Insert the wall hole sleeve C When bolts recessed in the concrete wall are to be utilized secure the installation plate 1 using 11 20 11 26 oval hole 450 mm pitch If the recessed bolt is too long change it for a shorter one available in the marke...

Page 4: ...lace the drain hose below the refrigerant piping Make sure that the drain hose is not heaved or snaked Do not pull the hose to apply the tape When the drain hose passes the room be sure to wrap insulation material obtainable at a store around it Wrap the felt tape 7 around the pipe and the drain hose then put the pipe in the back space of the indoor unit Drain hose Drain cap Cut off in case of lef...

Page 5: ...ening pull the wires lightly to confirm that they do not move O If the connecting wire is incorrectly connected to the terminal block the unit does not operate normally WARNING O A means for disconnection of the supply with an isolation switch or similar device in all active conductors shall be incorporated in the fixed wiring O Never cut the power cord and connect it to other wires It may cause a fi...

Page 6: ...ed for HFC refrigerant Torque wrench Yes 1 4 No 1 2 and 5 8 Flare tool Yes Clamp bar hole has been enlarged to reinforce the spring strength in the tool Flare gauge New Provided for flaring work to be used with R22 flare tool Vacuum pump adaptor New Provided to prevent the back flow of oil This adapter enables you to use existing vacuum pumps Electronic scale for refrigerant charging New It is difficu...

Page 7: ... 140 to 180 9 52 34 3 to 41 2 350 to 420 15 88 73 5 to 78 4 750 to 800 Tightening torque N m kgf cm Cap for service port 13 7 to 17 7 140 to 180 Cap for stop valve 19 6 to 29 4 200 to 300 Checking the remote infrared signal reception Press the ON OFF button on the remote controller and check that an electronic sound is heard from the indoor unit Press the ON OFF button again to turn the air condit...

Page 8: ...essor will be locked To maintain the high pressure of the gas cylinder warm the gas cylinder with warm water under 40 C during cold season But never use naked fire or steam 7 2 REMOVING THE INDOOR UNIT Remove the bottom of the indoor unit from the installation plate 1 Remove the front panel See FRONT PANEL REMOVAL shown above 2 Insert flat screwdrivers into the square holes at the left and right bot...

Reviews: