9-7. TEST POINT DIAGRAM AND VOLTAGE
1. Indoor power P.C. board
MS-CP13VA
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12)
Temperature (°C)
Resistance (kΩ)
Fuse (F11)
T3.15AL250V
Varistor (NR11)
Connector to indoor electronic
control P.C. board (CN20A)
5 V DC
12 V DC GND
Connector to
Indoor fan motor
(CN211)
Resistor (R111)
Connector to
Terminal block
(CN201)
(+)3-6 V DC
15 V DC
(-) GND
(High voltage DC)
311-325-339 V DC
(+)0 or 15 V DC
Timer short
mode point
(Refer to
7-1.)
Room temperature thermistor RT11 (CN111)
Connector
to Indoor
coil thermis-
tor RT12
(CN112)
Vane motor
(CN151)
Connector to indoor power
P.C. board (CN10A)
12 V DC
5 V DC
To disable "Auto restart function",
cut the Jumper wire to JR77.
(Refer to 7-3.)
Emergency operation
switch (E.O. SW) (SW1)