66
PCA-RP71HA
PCA-RP125HA
SYMBOL
[ LEGEND ]
NAME
SYMBOL
NAME
INDOOR POWER BOARD
INDOOR CONTROLLER BOARD
FUSE (T6.3AL250V)
MF1, MF2
C1, C2
H2
FAN MOTOR
CAPACITOR(FAN MOTOR)
DEW PREVENTION HEATER
VARISTOR
CONNECTOR (LOSSNAY)
CONNECTOR (REMOTE SWITCH)
CONNECTOR (HA TERMINAL-A)
CONNECTOR (CENTRALLY CONTROLL)
POWER SUPPLY (I. B)
POWER SUPPLY (R. B)
TRANSMISSION(INDOOR-OUTDOOR)
RELAY (DEW PREVENTION HEATER)
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
SWITCH (MODEL SELECTION) See Table 1.
SWITCH (CAPACITY CODE) See Table 2.
SWITCH (EMERGENCY OPERATION)
P. B
I. B
FUSE
ZNR
CN2L
CN32
CN41
CN51
LED1
LED2
LED3
X1
X4
X5
X6
SW1
TB2
TB4
TB5,TB6
TH1
TH2
TH5
R. B
TERMINAL BLOCK(INDOOR UNIT
POWER (OPTION))
TERMINAL BLOCK(INDOOR/OUTDOOR
CONNECTING LINE)
TERMINAL BLOCK(REMOTE CONTROLLER
TRANSMISSION LINE)
ROOM TEMP.THERMISTOR
(0˚C/15k
Ω
, 25˚C/5.4k
Ω
DETECT)
PIPE TEMP.THERMISTOR/LIQUID
(0˚C/15k
Ω
, 25˚C/5.4k
Ω
DETECT)
COND./ EVA.TEMP.THERMISTOR
(0˚C/15k
Ω
, 25˚C/5.4k
Ω
DETECT)
WIRED REMOTE CONTROLLER BOARD
SW2
SWE
Service board
SW1
Table 1
1 2 3 4 5
ON
OFF
Service board
SW2
Table 2
1 2 3 4 5
MODELS
PCA-RP71HA
ON
OFF
Service board
1 2 3 4 5
MODELS
PCA-RP125HA
ON
OFF
1 3 5 7
MF1
BLU
BLK
WHT
YLW
BLU
BLK
WHT
YLW
ORN
ORN
C1
RED
RED
1 3
1 3
1 3
1 2
1
2
1
2
3
1 3
1
1
6 5 4 3 2 1
MF2
BLU
YLW
YLW
ORN
BLK
RED
WHT
WHT
YLW
BLK
WHT
YLW
BLU
BLK
WHT
YLW
ORN
BRN
C2
GRY
RED
6 5 4 3 2 1
D.HEATER
CNC
(RED)
For PCA-RP125HA
X6 X5 X4
X6 X5 X4
ZNR
FUSE
SWE
FAN
(WHT)
SW2
SW1
LED3 LED2 LED1
H2
OFF
ON
1 2
1 2
1 2
1 2
1 3
1 2
WHT
WHT
REMOCON
CN22
(BLU)
TH1
TH2
TH5
BLU
BLU
BLK
BLK
1
2
2
1
TB5
INTAKE
CN20
(RED)
LIQUID
CN21
(WHT)
PIPE
CN29
(BLK)
R.B
TB6
TRANSMISSION WIRES DC12V
CN41
CN2L
CN32
CN51
ROWER
CNDK
(RED)
ROWER
CND
(ORN)
DC13.1V
CNDK
(RED)
CN2S
(WHT)
P.B
I.B
BRN
YLW
ORN
ORN
S1
S2
S3
TB4
TO
OUTDOOR
UNIT
ROWER
CN2D(WHT)
INDOOR/OUTDOOR
COMMUNICATION
CN3C(BLU)
Refer to tables 1
and 2 for service PCB.
Please set the voltage using the
remote controller.
For the setting method, please refer to
the indoor unit Installation Manual.
3
1
3
1
POWER
CND
(ORN)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
TB4
POWER
SUPPLY
~(1PHASE)
230V 50Hz
RED
TB2
BLU
TO
OUTDOOR
UNIT
L
S1
S2
S3
N
I.B
YLW
ORN
ORN
ORN
YLW
GRN/YLW
BRN
w
1 (Fig.1)
NOTES:
1.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3).
3.Symbols used in wiring diagram above are, : Connector, : Terminal (block).
1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1.
2 ; For power supply system of this unit, refer to the caution label located near this diagram.
OCS02-3.qxp 05.7.20 5:17 PM Page 66
Summary of Contents for Mr.Slim PU-P100VGAA
Page 56: ...56 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Page 57: ...57 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 60: ...60 PEAD RP35EA PEAD RP50EA PEAD RP60EA PEAD RP71EA PEAD RP100EA PEAD RP125EA PEAD RP140EA ...
Page 61: ...61 PEHD P35EAH PEHD P50EAH PEHD P60EAH PEHD P71EAH PEHD P100EAH PEHD P125EAH PEHD P140EAH ...
Page 62: ...62 PEAD P60GA PEAD P71GA PEAD P100GA ...
Page 77: ...77 8 2 PLA RP AA PLH P AAH 8 2 1 FRESH AIR INTAKE AMOUNT ...
Page 78: ...78 8 2 2 BRANCH DUCT Installation at site ...
Page 89: ...89 PEAD RP60GA PEAD RP71GA ...
Page 90: ...90 PEAD RP100GA ...
Page 95: ...95 ...