A-283
SPECIFICA
TIONS
CEILING
CASSETTE PM
CEILING CASSETTE PM SERIES Heat Pump R407C PMH-P1BA
Model
Item
Function
Capacity
Btu/h
W
Total input
kW
Model name
Power supply (phase, cycle,voltage)
Input
kW
Running current
A
Starting current
A
External finish
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Air flow (Lo-Mi2-Mi1-Hi)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Noise level (Lo-Mi2-Mi1-Hi)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
Weight
kg (lbs.)
Model name
Power supply (phase, cycle, voltage)
Input
kW
Running current
A
Starting current
A
External finish
Refrigerant control
Compressor
Model
Motor output
kW
Starter type
Protection devices
Heat exchanger
Fan (drive)
o
No.
Fan
Fan motor output
kW
Air flow
K
/ min (CFM)
Crankcase heater
W
Defrost method
Noise level
Dimensions
Cooling
dB
Heating
dB
W
mm (in.)
D
mm (in.)
H
mm (in.)
Outdoor unit
Refrigerant piping
Weight
kg (lbs.)
Refrigerant
Charge
kg (lbs.)
Oil (Model)
L
Pipe size O.D.
PMH-P1BA
Cooling
Heating
10,700
11,600
3,150
3,400
1.15
1.06
PMH-P1BA
Single phase, 50Hz, 220-230-240V
0.04
0.19
0.21
Galvanized sheets with gray heat insulation, grille munsell 0.98Y 8.99/0.63
Plate fin coil
Line flow fan (direct)
o
1
0.028
6.3-6.8-7.6-8.4 (222-240-268-297)
0 (direct blow)
–
Remote controller & built-in
29-31-33-35
26 (1)
UNIT : 812 (31-31/32) PANEL : 1000 (39-3/8)
UNIT : 395 (15-9/16)
PANEL : 470 (18-1/2)
UNIT : 230 (9-1/16)
PANEL : 30 (1-3/16)
UNIT : 14 (31)
PANEL : 3.0 (6.6)
PUH-P1VGAA
Single phase, 50Hz, 220-230-240V
1.11
1.02
4.92
4.52
30
Munsell 5Y 7/1
Linear expansion valve
Hermetic
RE189VHSMT
0.9
Line start
Internal thermostat, HP switch, Discharge thermo.
Plate fin coil
Propeller (direct)
o
1
0.070
45 (1,590)
30
Reverse cycle
46
48
900 (35-7/16)
330+20 (13+3/4)
650 (25-5/8)
50 (110)
R407C
1.7 (3.7)
0.57 (Ester) MEL56
6.35 (1/4)
12.7 (1/2)
Flared
Flared
Max. 30m
Max. 30m
Liquid
mm (in.)
Gas
mm (in.)
Connection method
Indoor side
Outdoor side
NOTE:
1. Rating conditions (ISO T1)
Cooling : Indoor
: D.B. 27
:
(80˚F), W.B. 19
:
(66˚F)
Outdoor
: D.B. 35
:
(95˚F), W.B. 24
:
(75˚F)
Heating : Indoor
: D.B. 20
:
(68˚F)
Outdoor
: D.B. 7
:
(45˚F), W.B. 6
:
(43˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
Lower limit
D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
Heating
Upper limit
D.B. 28˚C
D.B. 24˚C, W.B. 18˚C
Lower limit
D.B. 17˚C
D.B. -11˚C, W.B. -12˚C
Between the indoor &
outdoor units
Height difference
Piping length
3. Above data based on indicated voltage
Indoor unit
Single phase 240V 50Hz
Outdoor unit
Single phase 240V 50Hz
A.6.2
SPECIFICATIONS
A.6.2.1
Heat Pump (Refrigerant R407C)