12
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
k W
Service Ref.
Power supply (phase, cycle,voltage)
Input
k W
Running current
A
Starting current
A
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow
(Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
Weight
kg (lbs.)
Service Ref.
Power supply (phase, cycle, voltage)
Running current
A
Starting current
A
External finish
Refrigerant control
Compressor
Model
Motor output
kW
Starter type
Protection devices
Heat exchanger
Fan (drive)
o
No.
Fan
Fan motor output
kW
Airflow
K
/ min (CFM)
Crankcase heater
W
Defrost method
Sound level
Dimensions
Cooling
dB
Heating
dB
W
mm (in.)
D
mm (in.)
H
mm (in.)
Outdoor unit
Refrigerant piping
Weight
kg (lbs.)
Refrigerant
Charge
kg (lbs.)
Oil (Model)
L
Pipe size O.D.
PLA-P4AA.UK
Cooling
Heating
33,100
36,200
9,700
10,600
3.62
3.80
PLA-P4AA.UK
Single phase, 50Hz, 220-230-240V
0.26
0.26
1.25
1.25
2.0
2.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.120
20-23-26-28 (705-810-920-990)
0 (direct blow)
—
Remote controller & built-in
33-36-39-41
32 (1-1/4)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 298 (11-3/4)
PANEL : 30 (1-3/16)
UNIT : 30 (66)
PANEL : 5 (11)
PUH-P4YGA
3 phase, 50Hz, 380-400-415V (4wires)
5.49
5.79
45
Munsell 5Y 8/1
Linear expansion valve
Hermetic
NE56YDJM
2.7
Line start
Anti-phase protector, Thermal relay, Discharge thermo, HP switch
Plate fin coil
Propeller (direct)
o
2
0.070+0.070
85 (3,000)
38
Reverse cycle
51
53
900 (35-7/16)
330+20 (13+3/4)
1,260 (49-5/8)
96 (212)
R407C
4.0 (8.8)
1.6 (MEL56)
9.52 (3/8)
19.05 (3/4)
Flared
Flared
Max. 50m
Max. 50m
Liquid
mm (in.)
Gas
mm (in.)
Connection method
Indoor side
Outdoor side
Between the indoor &
outdoor units
Height difference
Piping length
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F)
W.B. 24
:
(75˚F)
Heating Indoor : D.B. 20
:
(68˚F)
Outdoor : D.B. 7
:
(45˚F)
W.B. 6
:
(43˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
3. Above data based on indicated voltage
Indoor unit
Single phase 240V 50Hz
Outdoor unit
3 phase 415V 50Hz
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
Heating
Upper limit D.B. 28˚C
D.B. 24˚C, W.B. 18˚C
Lower limit D.B. 17˚C
D.B. -11˚C, W.B. -12˚C