8
en
<Vent. setting>
<Returning to the Main menu>
3. Operation
Note:
●
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
●
Available directions depend on the type of unit connected.
●
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in “Standby” or “Defrost” states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
<[Manual] To Change the Airflow’s Left/Right Direction>
* The louver button cannot be used.
• Stop the unit operation, hold the lever of the louver, and adjust to the
desired direction.
* Do not set to the inside direction when the unit is in the cooling or dry-
ing mode because there is a risk of condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
3.6. Ventilation
For LOSSNAY combination
■
The following 2 patterns of operation is available.
•
Run the ventilator together with indoor unit.
•
Run the ventilator independently.
Press the [F1] or [F2] button.
Press the button as indicated above
to go through the following setting
options.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select “Swing” to move the vanes
up and down automatically.
When set to “Step 1” through
“Step 5”
, the vane will be fixed at
the selected angle.
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Select “Vane·Louver·Vent.
(Lossnay)” from the Operation
menu, and press the [SELECT/
HOLD] button.
Select “Operation” from the Main
menu (refer to 3.5.1), and press the
[SELECT/HOLD] button.
MENU
ON
OFF
RETURN SELECT
HOLD
Main
Main menu
Operation
F1
F2
F3
F4
MENU
ON
OFF
RETURN SELECT
HOLD
Main menu: RETURN
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
F1
F2
F3
F4
Press the [RETURN] button to go
back to the Main menu.
Press the [F4] button to go through
the ventilation setting options in the
order of “Off”, “Low”, and “High”.
* Settable only when LOSSNAY unit
is connected.
Off
Low
High
Off
Low
High
• The fan on some models of indoor
units may be interlocked with cer-
tain models of ventilation units.
MENU
ON
OFF
RETURN SELECT
HOLD
Main menu: RETURN
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
F1
F2
F3
F4
•
under the vane setting icon
This icon will appear when the vane
is set to “Step 5” and the fan oper-
ates at low speed during cooling or
drying operation (depends on the
model).
The icon will go off in an hour, and
the vane setting will automatically
change.
83
83
Fri
Room
Set temp.
Mode
Temp.
Fan
Cool
Auto
<Vane setting>
Fri
Low
Vent.
MENU
ON
OFF
RETURN SELECT
HOLD
F1
F2
F3
F4
MENU
ON
OFF
RETURN SELECT
HOLD
Fri
Off
Vent.
Vane
F1
F2
F3
F4
RH79A089H01_01en.indd 8
2020/12/25 13:27:39
009