6
en
3. Operation
■
About the operation method, refer to the operation manual that comes with each remote controller.
3.1. Turning ON/OFF
[ON]
[OFF]
Press the [ON/OFF] button.
The ON/OFF lamp will light up in green,
and the operation will start.
When “LED lighting” is set to “No,” the
ON/OFF lamp will not light up.
* Refer to the installation manual of
wired remote controller.
Press the [ON/OFF] button again.
The ON/OFF lamp will come off, and
the operation will stop.
■
Operation status memory
Remote controller setting
Operation mode
Operation mode before the power was turned off
Preset temperature
Preset temperature before the power was turned off
Fan speed
Fan speed before the power was turned off
■
Settable preset temperature range
Operation mode
Preset temperature range
Cool/Dry
19–30 ºC/67–87 °F
Heat
17–28 ºC/63–83 °F
Auto (single set point)
19–28 ºC/67–83 °F
Setback
[COOL] Preset temperature range for COOL mode.
[HEAT] Preset temperature range for HEAT mode. *1
Fan/Ventilation
Not settable
*1 The preset temperatures for cooling and heating can be set under the following conditions.
• The cooling preset temperature is greater than the heating preset temperature.
• The difference between the cooling and heating preset temperatures is equal or greater than the minimum temperature difference that varies depending on the indoor
unit model to be connected.
Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3 minutes.
This is to prevent the internal components from being damaged.
3.2. Mode Selection
Each pressing of the [F1] button cycles
through the following operation modes.
Select the desired operation mode.
Cool
Dry
Fan
Auto
Heat
• Operation modes that are not available to
the connected outdoor unit models will not
appear on the display.
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant
system (connected to the same outdoor unit) are already operated in a
different mode. In this case, the rest of the unit in the same group can
only be operated in the same mode.
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
83
83
MENU
ON
OFF
RETURN SELECT
HOLD
F1
F2
F3
F4
Automatic operation
<Single set point>
■
According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
■
During automatic operation, if the room temperature changes and
remains 2 °C, 4 °F or more above the set temperature for 15 minutes,
the air conditioner switches to cool mode. In the same way, if the room
temperature remains 2 °C, 4 °F or more below the set temperature for
15 minutes, the air conditioner switches to heat mode.
Cool mode
15 minutes (switches from
heating to cooling)
Set tempe2 °C, +4 °F
Set temperature
Set temperature −2 °C, −4 °F
15 minutes (switches
from cooling to heating)
■
Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees
cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).
Navigating through the screens
• To return to the Main screen ...... [RETURN] button
ON
OFF
ON
OFF