En-10
Air cleaning fi lter
(Electrostatic anti-allergy enzyme fi lter)
Every 3 months:
• Remove dirt by a vacuum cleaner.
When dirt cannot be removed by vacuum cleaning:
• Soak the fi lter and its frame in lukewarm water before rinsing it.
• After washing, dry it well in shade. Install all tabs of the air fi lter.
Every year:
• Replace it with a new air cleaning fi lter for
best performance.
• Parts Number
GM18/24:
MAC-2320FT
(with frame)
MAC-2321FT
(no frame)
GM30:
MAC-2310FT-E
(with frame)
MAC-2410FT-E
(no frame)
1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the above illustration.
• Wipe with a soft dry cloth or rinse it with water.
• Do not soak it in water for more than two hours.
• Dry it well in shade.
3. Install the front panel by following the removal procedure in reverse.
Close the front panel securely and press the positions indicated by
the arrows.
Air outlet and Fan (before cleaning, make sure that the fan is stopped)
C
LEANING
5
Install the horizontal vanes by
following the removal procedure
in reverse.
• If the horizontal vanes are not installed
correctly, all LED lamps blink when power
is turned on.
Note:
Do not apply excessive force to the fan or fan guard.
Instructions:
• Switch off the power supply or turn off the breaker before cleaning.
• Be careful not to touch the metal parts with your hands.
• Do not use benzine, thinner, polishing powder, or insecticide.
• Use only diluted mild detergents.
• Do not expose parts to direct sunlight, heat, or fi re to dry.
• Do not use water hotter than 50°C.
• Do not use a scrubbing brush, a hard sponge, or the like.
• Do not soak or rinse the horizontal vane.
• Do not apply excessive force on the fan as it may cause cracks or breakage.
Pull to remove from
the air fi lter
1
Turn the horizontal vane down-
ward. Then, remove the vane as
shown in
➀
and
➁
.
Vane
Unlock
Turn the horizontal vanes down-
ward. Then, remove the upper
vane as shown in
➀
and
➁
.
• Repeat
➀
and
➁
for the lower vane.
<GM18/24>
Upper vane
Unlock
2
Swing out the two vertical vanes
one by one.
3
Clean the air outlet and fan.
• Wipe with a soft dry cloth.
4
Put the vertical vanes back to their
original positions correctly one by
one, into their respective guide.
• Push the vanes until they click into place.
Guide
<GM30>
<GM30>
Front panel
<GM18/24>
Hinge
GM30 only
Hole
Air fi lter (Nano platinum fi lter)
•
Clean every 2 weeks
• Remove dirt by a vacuum cleaner, or rinse with water.
• After washing with water, dry it well in shade.
What is “Nano platinum fi lter”?
Nano platinum is a ceramic particle that includes a platinum nanoparticle.
The particles are incorporated into the fi lter material, which results in pro-
viding semi-permanent antibacterial and deodorizing characteristics for the
fi lter. Nano platinum surpasses the catechin (a biofl avonoid that is found in
green tea) in performance. Nano platinum fi lter uses this compound not only
to improve air quality but also to eliminate bacteria and viruses. This air fi lter
has a semi-permanent lasting effect even after washing it with water.
Important
•
Clean the fi lters regularly for best performance and to
reduce power consumption.
•
Dirty fi lters cause condensation in the air conditioner
which will contribute to the growth of fungi such as
mold. It is therefore recommended to clean air fi lters
every 2 weeks.
JG79A888H02_en.indd 10