NSTALLATION PLACE AND
ELECTRICAL WORK
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
S
PECIFICATIONS
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
Page 5
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter.
Page 8
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the ground wire is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions.
Page 4
To prevent the
effects of a
fl uorescent lamp,
keep as far apart
as possible.
wall, etc.
Inverter-type
fl uorescent lamp
Keep a space
to prevent
the picture
distortion or
the noise.
Radio
Well- ventilated
dry place
Refer to the instal-
lation manual of
outdoor unit.
TV
Cordless
phone or
Portable
phone
Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit
90°F (32.2°C) DB
115°F (46.1°C) DB
73°F (22.8°C) WB
—
Lower limit
67°F (19.4°C) DB
14°F (-10°C) DB
57°F (13.9°C) WB
—
Heating
Upper limit
80°F (26.7°C) DB
75°F (23.9°C) DB
—
65°F (18.3°C) WB
Lower limit
70°F (21.1°C) DB
6°F (-14.4°C) DB
—
5°F (-15°C) WB
DB : Dry Bulb
WB : Wet Bulb
Note:
If the outdoor temperature is below the lower limit of guaranteed operating
range, the outdoor unit may stop operation until the outdoor temperature
exceeds the lower limit.
The installation location of the outdoor
unit should be at least 10 ft (3 m) away
from the antennas for TV sets, radios,
etc. In areas where the reception is weak,
provide greater space between the out-
door unit and the antenna of the affected
device if operation of the air conditioner
interferes with radio or TV reception.
3 ft (1 m)
or more
3 ft (1 m)
or more
10 ft (3 m)
or more
En-10