background image

En-2

 CAUTION

Do not step on an unstable bench to operate or clean the

unit.

• This may cause injury if you fall down.

Do not pull the power cord.

•  This may cause a portion of the core wire to break, which may 

cause overheating or 

fi

 re.

Do not charge or disassemble the batteries, and do not

throw them into a 

fi

 re.

• This may cause the batteries to leak, or cause a 

fi

 re or explosion.

Do not operate the unit for more than 4 hours at high hu-

midity (80% RH or more) and/or with windows or outside 

door left open.

•  This may cause the water condensation in the air conditioner, 

which may drip down, wetting or damaging the furniture.

•  The water condensation in the air conditioner may contribute 

to growth of fungi, such as mold.

Do not use the unit for special purposes, such as storing 

food, raising animals, growing plants, or preserving preci-

sion devices or art objects.

• This may cause deterioration of quality, or harm to animals

and plants.

Do not expose combustion appliances to direct air

fl

 ow.

• This may cause incomplete combustion.

Never put batteries in your mouth for any reason to avoid

accidental ingestion.

• Battery ingestion may cause choking and/or poisoning.

Before cleaning the unit, switch it OFF and disconnect the

power plug or turn the breaker OFF.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

When the unit will be unused for a long time, disconnect the

power plug or turn the breaker OFF.

•  The unit may accumulate dirt, which may cause overheating 

or 

fi

 re.

Replace all batteries of the remote controller with new ones

of the same type.

•  Using an old battery together with a new one may cause over-

heating, leakage, or explosion.

If the battery 

fl

 uid comes in contact with your skin or clothes,

wash them thoroughly with clean water.

•  If the battery 

fl

 uid comes in contact with your eyes, wash them 

thoroughly with clean water and immediately seek medical 

attention.

Ensure that the area is well-ventilated when the unit is 

operated together with a combustion appliance.

• Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a 

possibility of a lightning strike.

• The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, perform

inspection and maintenance in addition to normal cleaning.

•  Dirt or dust in the unit may create an unpleasant odor, contribute 

to growth of fungi, such as mold, or clog the drain passage, and 

cause water to leak from the indoor unit. Consult your dealer 

for inspection and maintenance, which require specialized 

knowledge and skills.

Do not operate switches with wet hands.

• This may cause electric shock.

Do not clean the air conditioner with water or place an object 

that contains water, such as a 

fl

 ower vase, on it.

• This may cause 

fi

 re or electric shock.

Do not step on or place any object on the outdoor unit.

• This may cause injury if you or the object falls down.

S

AFETY PRECAUTIONS

For installation

 WARNING

Consult your dealer for installing the air conditioner. 

•  It should not be installed by the user since installation requires 

specialized knowledge and skills. An improperly installed air 

conditioner may cause water leakage, 

fi

 re, or electric shock.

Provide a dedicated power supply for the air conditioner.

•  A non-dedicated power supply may cause overheating or 

fi

 re.

Do not install the unit where 

fl

 ammable gas could leak.

•  If gas leaks and accumulates around the outdoor unit, it may 

cause an explosion.

Earth the unit correctly.

•  Do not connect the earth wire to a gas pipe, water pipe, light-

ning rod, or a telephone ground wire. Improper earthing may 

cause electric shock.

 CAUTION

Install an earth leakage breaker depending on the installa-

tion location of the air conditioner (such as highly humid 

areas).

•  If an earth leakage breaker is not installed, it may cause electric 

shock.

Ensure that the drain water is properly drained.

•  If the drain passage is improper, water may drip down from 

the indoor/outdoor unit, wetting and damaging the furniture.

In case of an abnormal condition

  Immediately stop operating the air conditioner and consult your dealer.

   IMPORTANT

Dirty 

fi

 lters cause condensation in the air conditioner which will contribute

to the growth of fungi such as mold. It is therefore recommended

to clean air 

fi

 lters every 2 weeks.

Summary of Contents for Mr.Slim MCF-GN13VA

Page 1: ...glish OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating instructions before use SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MCF GN13VA MCF GN18VA MCF GN24VA ...

Page 2: ...s death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Children should be supervised to ensure that they do not play with the appliance Do not insert your finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside rotates at high speeds during operation In case of an abnormal ...

Page 3: ...rvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons perform inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor contribute to growth of fungi such as mold or clog the drain passage and cause w...

Page 4: ...er batteries Setting current time NAME OF EACH PART PREPARATION BEFORE OPERATION 1 Remove the front lid 2 Insert the negative pole of AAA alkaline batteries first 3 Install the front lid 4 Press RESET 1 Press CLOCK 3 Press CLOCK again 2 Press the TIME buttons to set the time Each press increases decreas es the time by 1 minute 10 minutes when pressed longer Indoor unit Remote controller Deodorizin...

Page 5: ...anged when the room temperature is more than 2 C higher than the set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature COOL mode Enjoy cool air at your desired temperature DRY mode Dehumidify your room The room may be cooled slightly Temperature cannot be set during DRY mode FAN mode Circulate the air in your room Emergency operation When th...

Page 6: ...ing COOL DRY when the vane is set to position 4 or 5 vane automatically moves to position 1 after 1 hour to prevent water dripping Swing The vane moves up and down intermittently To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press or during operation to set the timer ON timer The unit will turns ON at the set time OFF timer The unit will tur...

Page 7: ...r outlet The air cleaning filter is disposable If the color of the filter turns brown replace the filter at once Replace it with a new air cleaning filter every 4 months for best performance Parts Number MAC 1200FT with frame Parts Number MAC 1600FT no frame Note Clean the filters regularly for best performance and to reduce power consumption Air filter Catechin air filter Clean every 2 weeks Remo...

Page 8: ...planation Check points Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the polarity of the batteries correct Page 3 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temp...

Page 9: ...eception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 4 This dries the inside of the unit 2 Press to stop the operation 3 Turn off the breaker and or disconnect the power supply plug 4 Remove all batteries from the remote controller When using the air conditioner again 1 Clean the air filter Page 6 2 Check that the air inlet and outlet of the indoor and ou...

Page 10: ...เกิดอันตรายร าย แรง เช น เสียชีวิต บาดเจ บสาหัส เป นต น ข อควรระวัง หากใช งานไม ถูกต อง อาจทําให เกิดอันตรายร ายแรงได ตามป จจัย แวดล อม ห ามสอดนิ ว ไม หรือวัตถุอื นใด เข าไปในช องลมเข าและช องลมออก มิฉะนั นอาจทําให บาดเจ บได เนื องจากในขณะที เครื องทํางาน พัดลมที อยู ด านใน จะหมุนด วยความเร วสูง หากมีสิ งผิดปกติเกิดขึ น เช น กลิ นเหม นไหม ควรหยุดใช เครื องปรับอากาศ และถอดปลั กไฟออก หรือสับเบรกเกอร...

Page 11: ...ีการเผาไหม หากอากาศถ ายเทไม เพียงพออาจทําให ขาดออกซิเจนได สับเบรกเกอร ลงเมื อฝนฟ าคะนองเพราะอาจเกิดฟ าผ าได เครื องอาจชํารุดหากฟ าผ า เมื อใช งานเครื องมานานหลายฤดูกาลแล ว ควรทําการตรวจสอบ และซ อมบํารุงเพิ มเติมนอกเหนือจากการทําความสะอาดปกติ สิ งสกปรกหรือฝุ นละอองในเครื องอาจทําให เกิดกลิ นอันไม พึงประสงค ทําให เกิดเชื อราต างๆ หรืออุดตันช องระบายจนทําให มีนํ ารั วไหลออกจากเครื อง ภายในอาคารได ขอค...

Page 12: ...ี ของรีโมทคอนโทรล การตั งเวลาในป จจุบัน ูู ชื อชิ นส วน ใ ไ การเตรียมพร อมก อนการใช งาน 1 ถอดฝาหน าออก 2 ใส แบตเตอรี อัลคาไลน ขนาด AAA โดยใส ด านที เป นขั วลบก อน 3 ใส ฝาหน าเข าไป 4 กด RESET 1 กด CLOCK 3 กด CLOCK อีกครั ง 2 กดปุ ม TIME เพื อตั งเวลา ในการกดแต ละครั ง จะเพิ ม ลดเวลา 1 นาที 10 นาที หากกดค างไว เครื องภายในอาคาร รีโมทคอนโทรล แผ นกรองขจัดกลิ น ชิ นส วนอุปกรณ เสริม ช องลมเข า ด านหลัง...

Page 13: ...แปลง หากอุณหภูมิห องสูง กว าอุณหภูมิที ตั งไว มากกว า 2 ในกรณีนี ควรรอจนกว าอุณหภูมิจะลดลงโดยสูงกว าอุณหภูมิที ตั ง ไว ไม เกิน 2 C โหมดทําความเย น COOL ใช กําหนดความเย นตามอุณหภูมิที ต องการ โหมดระบายความชื น DRY ลดความชื นภายในห อง ห องอาจเย นไม มากนัก โหมดระบายความชื น ไม สามารถตั งค าอุณหภูมิได โหมดพัดลม FAN หมุนเวียนอากาศภายในห อง การทํางานฉุกเฉิน เมื อไม สามารถใช งานรีโมทคอนโทรลได เป ดการทําง...

Page 14: ...DRY ในระหว างทําความเย น COOL ระบายความชื น DRY เมื อตั งใบพัดไว ในตําแหน ง 4 หรือ 5 ใบพัดจะ เคลื อนไปยังตําแหน ง 1 โดยอัตโนมัติ เมื อเวลาผ านไปประมาณ 1 ชั วโมง ทั งนี เพื อป องกันไม ให นํ าหยด ส าย ใบพัดจะขยับขึ นและลงเป นระยะ การเปลี ยนทิศทางการระบายลมแอร ในแนวนอน ขยับใบพัดแนวนอนด วยตนเองก อนจะเป ดเครื องให ทํางาน 1 กด หรือ ในระหว างการทํางานเพื อตั งนาฬ กาจับเวลา ตั งเวลาเป ด เครื องจะเป ดตามเว...

Page 15: ...หากสีของแผ นกรองคลํ าลง ควรเปลี ยนแผ นกรองชุดใหม ทันที เปลี ยนแผ นกรองชุดใหม ทุกๆ 4 เดือน เพื อให คงประสิทธิภาพในการทํางานสูงสุด หมายเลขชิ นส วน MAC 1200FT พร อมโครง หมายเลขชิ นส วน MAC 1600FT ไม มีโครง หมายเหตุ ทําความสะอาดแผ นกรองเป นประจําเพื อให คงประสิทธิภาพในการทํางานสูงสุดและช วยลด การสิ นเปลืองพลังงาน แผ นกรองอากาศ แผ นกรองคาเทชิน Catechin ทําความสะอาดทุก 2 สัปดาห กําจัดฝุ นละอองออกโดยใช เ...

Page 16: ...คําอธิบายและจุดตรวจสอบ รีโมทคอนโทรล หน าจอของรีโมทคอนโทรลจะไม แสดง ผลใดๆ หรือหน าจอเลือนลาง เครื อง ภายในอาคารจะไม ตอบสนองต อ สัญญาณรีโมทคอนโทรล แบตเตอรี หมดหรือไม หน า 3 ใส แบตเตอรี ถูกต องตามขั ว หรือไม หน า 3 กดปุ มใดปุ มหนึ งบนรีโมทคอนโทรลของเครื องใช ไฟฟ าอื น อยู หรือไม ไม เย น ห องเย นไม พอ ตั งค าอุณหภูมิไว ถูกต องหรือไม หน า 4 ตั งค าพัดลมไว ถูกต องหรือไม ควรเปลี ยนความแรงพัดให แรงขึ น แผ...

Page 17: ...มเย น COOL ที ปรับตั งค าเอง แล วใช งาน ประมาณ 3 ถึง 4 ชั วโมง หน า 4 ซึ งจะช วยให ด านในของเครื องแห ง 2 กด เพื อหยุดการทํางาน 3 สับเบรกเกอร ลง และ หรือถอดปลั กไฟออก 4 ถอดแบตเตอรี ทั งหมดออกมาจากรีโมทคอนโทรล เมื อกลับมาใช งานเครื องปรับอากาศอีกครั ง 1 ทําความสะอาดแผ นกรอง หน า 6 2 ตรวจสอบว าไม มีสิ งใดมาอุดตัดช องลมเข าและช องลมออกในเครื องภายในอาคาร และภายนอกอาคาร 3 ตรวจสอบว าต อสายดินไว ถูกต อง...

Page 18: ...VN79C791H01 HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Reviews: