22
For the symptoms listed below, refer to the remedies listed right.
The dehumidifi er does not have a cooler function. Due to heat produced
during operation, the room temperature may rise 3-6°C.
(If operation is performed with the unit set to Dehumidifying “LOW” or “AUTO”,
the rising of the room temperature can be minimized compared to other
operating modes.)
The room temperature rises
during operation
(The unit blows warm air)
Symptom
Cause/Remedy
Check to see if the power cord is correctly plugged.
Plug the power cord properly into the power socket.
→
Is the air intake or air outlet blocked?
Remove the item that is blocking it.
→
Is operation being performed with the unit set to Dehumidifying AUTO?
The unit is switching between the dehumidifying operation, blowing
operation, and stop state automatically.
→
Is operation being performed with the unit set to Bathroom Mildew
Guard?
Operation stops automatically if the humidity falls. Operation stops
after a minimum of 4 hours.
→
Is operation being performed with the unit set to “Intelligent Laundry”?
Operation stops after approximately 1 hour if the room temperature
is approximately 5°C or less. This is because the evaporation of
moisture from clothes becomes diffi cult and humidity does not
change if the room temperature is low.
→
Is operation being performed with the unit set to DEO-DRY?
This operation is designed to end after approximately 1 hour.
→
Check to see if the water tank is full.
Empty the water tank and return it to its original position.
→
Check to see if the water tank is inserted properly.
Adjust the position of the water tank.
→
I am being notifi ed that it is time to clean the silver ion fi lter, air intake,
and sensor.
Clean them as described in "Maintenance," and then reset the lamp
by pressing the RESET switch until you hear a beep.
→
Has the room temperature become high (approximately 40°C or more)?
Operation sometimes stops to prevent the temperature inside the unit
from rising. Reset the lamp by pressing the RESET switch until you
hear a beep.
→
Is the air intake or air outlet blocked?
Remove the item that is blocking it, and then reset the lamp by
pressing the RESET switch until you hear a beep.
→
Is the silver ion fi lter clogged?
Clean it as described in “Maintenance.”
→
Is the air intake or air outlet blocked?
Remove the item that is blocking it.
→
Do the temperature and humidity become low?
The amount of dehumidifying becomes less as the temperature and
humidity in the room drops.
Water does not collect in
the water tank (minimal
dehumidifying results)
The unit does not operate (No
air comes out and the louvre
does not swing)
The unit stops
Flashing or on
Indicates
Check to see if the room is not too large.
Check to see if the exits to the room are open.
Refrain from opening doors/windows during operation.
→
Check to see if steam producing appliances such as kerosene heaters are on in the vicinity.
The humidity level does not
drop easily
Press the Swing louvre switch again.
The louvre does not move as set
Even if the POWER switch is turned off, the blower fan rotates for
approximately 2 minutes to prevent the temperature inside the unit from
rising. Wait until the blower fan stops before removing the power plug.
The unit continues to operate
even though it is turned off
Stops after
a short time
Indicates
P19
P5
P3
P8
P5
P9
P12
P10
P13
P16
P8
P15·19
P15
P5
P15·19
P9
P14
Is the unit tilted or in a non-upright position?
Did you carry the unit without emptying the water from the tank?
Is the fl oating element disconnected?
Is the tank cracked or broken?
Purchase a new tank for replacement.
→
Water leaks from the unit
Troubleshooting
e̲mj̲ez6cx̲s1.indb 22
e̲mj̲ez6cx̲s1.indb 22
2010/05/17 10:28:16
2010/05/17 10:28:16