Mitsubishi Electric MJ-EZ6CX-S1-IT Instruction Manual Download Page 12

12

Changes with 
every press. 

The BATHROOM MILDEW GUARD lamp lights.

 

The swing louvre operation starts

 (blowing 

set to “WIDE” and “FRONT”).

Operation stops after approximately 4 to 12 hours. 

The POWER lamp and BATHROOM MILDEW 
GUARD lamp turn off.

About Bathroom Mildew Guard Operation

After dehumidifying is performed until the humidity reaches 50%, 
operation is performed for approximately 4 hours and then stopped 
automatically. The operation time varies depending on the temperature 
and humidity, but the minimum time is approximately 4 hours 
(approximately 6 hours when the room temperature is 20°C or less) and 
the maximum time is approximately 12 hours.

How is mildew growth suppressed?

Mildew is unable to produce new spores if dried as mycelia. The Mildew Guard feature applies 
this principle. (However, the spores themselves are resilient to dry conditions.)

Installing the Dehumidifi er

Reducing Growth of Mildew in Bathroom (Bathroom Mildew Guard)

This operation is for reducing the growth of mildew by drying the inside of a bathroom to remove any humidity and droplets that 
remain inside after, for example, you take a bath. This operation can also be used as a measure for tackling mildew in rooms.

Information

For effective use, keep the windows and doors of the room closed and do not ventilate the room during operation. 
Operation may not be suffi ciently effective if the bathroom is spacious or because of the building materials used for the 
fl oor and walls of the bathroom. 
Drops of water may remain in places where water collects easily. 
Mildew may grow depending on the room conditions and the type of mildew. 
Example: Where air circulation is poor such as beneath a container or the like in the bathroom or at the back of a cupboard 
or behind furniture in the bathroom.
This operation cannot dry locations where the airfl ow cannot reach such as inside a bathtub and beneath a container.
This operation cannot remove existing mildew and water scale, or slime in the drain outlet. 
If this operation is used in conjunction with the off timer, operation may stop before drying is complete. 

If water remains in the 
bathtub, cover the bathtub. 

Set air to be blown from 
the front of the unit. 

Adjust the orientation of 
the unit so that air fl ows 
toward the whole room.

<Preparation> Install the dehumidifi er in the dressing room

Use the “downward blowing louvre” operation

.

 

1

Press 

2

Press 

 to select 

“BATHROOM MILDEW GUARD”.

<When you want to abort the operation>

When you want to end the operation partway through: 

Press the POWER switch (OFF).

When you want to switch to another operation:

Press any one of the “INTELLIGENT LAUNDRY”, 
“DEHUMIDIFYING”, and “MODE” switches. 

Install the unit in the dressing room (entrance to 
the bathroom).
(Do not install the unit inside the bathroom.)

Humidity 50%

Operation time

Swing direction

Start of 
operation

End of 

operation

WIDE

FRONT

Varies depending on the 
temperature and humidity

4 hours

“Identifi cation of Black Mold”
[Research paper by Dr.K.Abe of the 
Environmental Biology Research Center]

Rough Guide on Usage

Location to be dehumidifi ed

Size

Bathroom (ba 
dressing room)

Up to approximately 7 m

2

 (size of 

ba dressing room)

Room

Up to 9 m

2

For more effective operation, use the unit within the above ranges.

Do not use the unit in a bathroom or other 
location where it is likely to come into contact 
with water, or wash it with water.

The unit does not have a drip-proof or water-proof 
structure. Water coming into contact with the unit may 
result in a fi re due to a short circuit, or an electric shock.  

CAUTION

 The louvre operates in the “WIDE” swing direction 

until the humidity drops to 50% and then 
automatically switches to the “FRONT” swing 
direction. The swing direction can be changed 
according to preference. 

 The airfl ow rate cannot be set because it is 

changed automatically. Do not use this operation in 
conjunction with other operations.

P9

P14

P14

e̲mj̲ez6cx̲s1.indb   12

e̲mj̲ez6cx̲s1.indb   12

2010/05/17   10:28:15

2010/05/17   10:28:15

Summary of Contents for MJ-EZ6CX-S1-IT

Page 1: ...dew Guard 12 Removing Odor from Clothes Clothes Deodorant 13 Using Louvre 14 Using OFF Timer 15 CLEAN FILTER Lamp 15 Draining 16 Continuous Drainage 17 Troubleshooting Maintenance 18 Replacement Parts 21 Storage and Disposal 21 Troubleshooting 22 Specifications 24 In order to ensure correct usage please read this instruction manual carefully and retain it for future reference Before accepting the ...

Page 2: ... Recommended Ways of Using the Unit P 9 P 10 HIGH When you are worried about mildew in the bathroom P 12 BATHROOM MILDEW GUARD Reducing blowing sound and performing continuous operation LOW P 9 When you want to perform continuous operation HIGH P 9 When you want to perform continuous operation HIGH P 9 When you want to perform automatic operation AUTO P 9 P 13 DEO DRY e mj ez6cx s1 indb 2 e mj ez6...

Page 3: ...ith the power consumption of the heater reduced to a level equivalent to that of LOW mode z The blown air may cause smell during operation An odor may be emitted from the parts inside the dehumidifier when you first use the dehumidifier Odorants that cannot be removed by the silver ion filter may be absorbed by the dehumidifier rotor inside the unit Odors unique to zeolite sour smell burning smell etc ...

Page 4: ...power plug after the blower fan has stopped Do not put the unit near heat generating devices such as stoves fan heaters etc The plastic parts may melt and cause fire Do not put your fingers or any long object into the air intake outlet Do not touch the swing louver The internal fan rotates at high speeds and such actions may result in injury or malfunctions Do not attempt to repair disassemble or ...

Page 5: ...a prolonged period of time Be especially careful when using the unit where there is someone who is unable to adjust the humidity infant child or elderly person If air flow is directed at the body for long periods it may harm one s physical condition and lead to dehydration Do not stand on sit on or lean against the unit The unit may tip over causing injury Do not remove the Styrofoam from the float...

Page 6: ...and art work are vulnerable to dry air as it may cause cracks and warping Keep the unit always in an upright position Inclining the unit may cause water in the tank to leak into the unit resulting in malfunction Should you incline the unit accidentally contact the place of purchase for advice Do not carry the unit horizontally This may result in malfunctions Warnings Names and Front Back Precautio...

Page 7: ...rbon monoxide cannot be removed with this filter POWER lamp Lights during operation POWER switch Turns the power on off P15 19 CLEAN FILTER lamp Flashes or lights to notify you that it is time to clean the filter RESET switch Cancels the flashing or lit state of the CLEAN FILTER lamp Control panel FULL lamp Lights when the tank is full Lights when the tank is not attached to the unit OFF TIMER lamps ...

Page 8: ... filter is supplied with the unit at time of purchase Please fit before using the unit Set the filter cover 4 1 Insert the tabs at the bottom of the filter cover into the unit 2 Push in the filter cover at the top Remove the silver ion filter from the polyethylene bag 1 Remove the filter cover 2 Hold the top of the filter cover and pull it toward you and remove it Filter cover Set the silver ion filter...

Page 9: ...ns may stop Rough Guide on Usage Size of room Up to approx 9m2 Keep usage within the ranges specified in Rough Guide on Usage to ensure efficient operation If the room is large the humidity level may not fall to the set humidity level z z z 1 2 Press Press to select the operating mode To stop operation The POWER lamp turns off The operating mode lamp turns off Air is blown for approximately 2 minute...

Page 10: ... the plug is disconnected or the power turned off the unit restarts at the previous setting The swing setting is not remembered Information To stop operation The POWER lamp turns off The operating mode lamp turns off Air is blown for approximately 2 minutes and then operation stops and the louvre closes automatically Press Information To prevent the temperature inside the unit from rising the blow...

Page 11: ...them Guideline for spacing Approximately 5 cm Hang any difficult to dry items in positions where wind can easily come into contact with them Clothes placed close together will take time to dry Drying takes a long time in the following cases When there are a lot of clothes When the room temperature is low The drying time required at a low temperature approximately 10 C is around 1 5 times that at a...

Page 12: ... container This operation cannot remove existing mildew and water scale or slime in the drain outlet If this operation is used in conjunction with the off timer operation may stop before drying is complete If water remains in the bathtub cover the bathtub Set air to be blown from the front of the unit Adjust the orientation of the unit so that air flows toward the whole room Preparation Install the...

Page 13: ...on that enables a good amount of wind to blow the clothes 3 Press to select the louvre swing direction When you want to abort the operation When you want to end the operation partway through Press the POWER switch OFF When you want to switch to another operation Press any one of the INTELLIGENT LAUNDRY DEHUMIDIFYING and MODE switches Details on Clothes Deodorant Operation This operation takes appr...

Page 14: ...rolled to send air at clothes from all angles The blowing range is approximately 90 FRONT When you want to dehumidify the inside of closets etc z The louvre swings so that air is blown from the front of the unit The blowing range is approximately 60 WIDE To cover the entire room z The louvre swings so that air is blown over a wide area The blowing range is approximately 145 The moving range of the...

Page 15: ...CLEAN FILTER Lamp When it becomes time to clean the silver ion filter and air intake you are notified by the flashing or lighting of the CLEAN FILTER lamp Press the POWER switch to turn off the power and then make sure you perform cleaning before pressing the RESET button CLEAN FILTER lamp flashes Clean the silver ion filter and air intake and then insert the power plug and press the RESET switch unti...

Page 16: ...e lamp turns off Not attaching the tank lid properly may result in water leaking If the tank lid is not inserted firmly it may not be possible to remove the tank If the tank is not installed correctly the tank full light will come on and the unit will not operate Note Do not remove or dismantle the floating element in the tank If it is removed the unit cannot detect when the tank is full and this co...

Page 17: ...ank to the unit and place the end of the hose in the drain location 5 If the tank is not reattached the FULL lamp remains on and operation is not possible Hose Drain Note When you will perform continuous drainage leave at least 20 cm of space from the surface with the outlet for the hose Confirm that the hose does not show signs of deterioration such as bending cracks and clogging Inspect the hose ...

Page 18: ...on filter Air intake Sensor Clean with a vacuum cleaner Once every two weeks Silver ion filter Soak in water Once every three months Water tank Unit Wipe with a soft cloth The unit draws in dust present in the air and this may cause the tank to gradually become dirty If the dirt does not come off easily wash with cold or warm water then wipe with a soft dry cloth Mildew may form in the tank unless...

Page 19: ... This may damage the filter When the filter is very dirty Soak the filter in water Remove the filter cover Clean the filter Clean the air intake and sensor 4 Remove any dirt with a vacuum cleaner Do not use a nozzle with a brush This may damage the filter Set the silver ion filter into the filter cover 5 Make sure the silver ion filter is attached to the unit If it is not fine dust will enter inside the...

Page 20: ...like to scrub the filter or rub the filter while soaking This may damage the filter Dry the silver ion filter well 5 Once Every Three Months Dry the filter on a flat surface Press the POWER switch to turn off the power wait until the blower fan stops rotating approximately 2 minutes before unplugging the power cord Any yellow or dark stains may remain on the filter but should not affect performance The ...

Page 21: ... sterilizing and deodorizing filter for replacement Type MJPR 7AXFT Please contact your nearest Mitsubishi Electric dealer for purchase Storage and Disposal Remove the drainage water Clean the silver ion filter Clean the air intake Store the unit 5 When you are sure that all parts of the nit are dry cover it with a cloth to keep it from dust Store the unit in an upright position in a place not exp...

Page 22: ...pressing the RESET switch until you hear a beep Has the room temperature become high approximately 40 C or more Operation sometimes stops to prevent the temperature inside the unit from rising Reset the lamp by pressing the RESET switch until you hear a beep Is the air intake or air outlet blocked Remove the item that is blocking it and then reset the lamp by pressing the RESET switch until you he...

Page 23: ...umidifier rotor inside the dehumidifier Also that absorbed odor will be heated by the heater which may result in a burning like smell or other abnormal odor Examples Cigarettes cosmetics hair dressing products building materials new furniture etc The unit produces an odour Check to see if the unit is on a slope or uneven surface Move to a sturdy even surface Check to see if the silver ion filter is c...

Page 24: ...cause the three spots shown are fastened with three special screws If the supply cord is damaged it must be replaced by the manufacturer its service agent in order to avoid a hazard NOTE Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at their end of ...

Reviews: