Troubleshooting

¡

For the symptoms listed below, refer to the remedies listed right.

Symptom

Cause/Remedy

The unit blows warm air

Water does not collect in
the water tank (minimal
dehumidifying results)

The unit does not turn on
(no air comes out)
The unit keeps turning off

The humidity level does
not reach the level set

The unit continues to
operate even though it is
turned off

The water tank contains
liquid or white water
residue

There is black residue on
the inside of the water tank
and lid

¡

Dehumidified air passes through heating coils causing it to
warm (this unit is not a cooler). This is not a malfunction.

¡

Check to see if the temperature/humidity is low.
Low room temperature/humidity reduces dehumidifying
effectiveness (in winter, the air is cooler reducing the amount
of water collected).
This is not a malfunction.

¡

Check to see if the power cord is correctly plugged.

Plug the power cord properly into the power socket.

¡

Check to see if anything is blocking the air intake or outlet.

Remove the obstruction.

¡

Check to see if the pre-filter is clogged.

Clean according to the maintenance procedures.

¡

Check to see if the unit is in AUTO.
The unit is automatically controlling the dehumidifier, fan, and
standby times.

¡

Check to see if the water tank is full.

Empty the water tank and return it to its original position.

¡

Check to see if the water tank is inserted properly.

Adjust the position of the water tank.

¡

Check to see if the unit is in defrosting mode.
The unit activates defrosting mode when the room temperature
drops below 15

°

C. The dehumidifier and blower functions stop

during defrosting.

¡

Check to see if the room is not too large.

¡

Check to see if the exits to the room are open.

Refrain from opening doors/windows during operation.

¡

Check to see if steam producing appliances such as kerosene
heaters are on in the vicinity.

¡

Is the unit set to drying inside mode?
This function activates automatically after the unit finishes
operating.

¡

The residue is from final product testing at the factory. It is not
a result of a malfunction.

¡

The residue is from debris in the air.

Clean according to the maintenance procedures.

Lights

Indicates

14

8

2

8

4

14

10

7

11

12

7·12

e_mj_e16v_s1(10_18)_e33.qx  6/8/05 2:57 PM  Page 16

Summary of Contents for MJ-E16V-S1

Page 1: ... ON To turn OFF Setting modes 10 AUTO LOW LAUNDRY LOW TEMP and AIR PURIFIER Drying inside 11 Using the OFF Timer 12 Removing Water from the Tank 12 Continuous Drainage 13 Maintenance 14 Replacing the Air Purifying Filter 15 Storage and Disposal 15 Troubleshooting 16 Specifications 18 In order to ensure correct usage please read this instruction manual carefully and retain it for future reference B...

Page 2: ...ifier seem to collect less water in winter Q Why doesn t the dehumidifier operate Why does the unit stop operating suddenly A The unit might be in AUTO mode The unit automatically switches between dehumidifying airflow only and non operation 10 A When the temperature and humidity are low the amount of water collected is decreased In winter because the temperature is lower than in summer the effect...

Page 3: ...ff the power plug and insert the plug firmly If the plug is not fully inserted into the socket dust may gather on the connectors which may cause fire and or electric shock Use 220 240V AC power sockets Connecting to power sockets other than 220 240V AC may result in fire and or electric shock Remove water that has collected in the tank Accidentally drinking the water or using it for other purposes...

Page 4: ... one s physical condition and lead to dehydration Install the unit in a location where the floor is flat and stable If the unit falls over the water collected in the water tank may leak damaging surrounding objects and in turn result in fire or electric shock caused by an electrical leak Grasp the plug and remove from the power socket When removing the plug from the power socket do not pull on it ...

Page 5: ...the power source when cleaning it When the unit is on the internal fan rotates at high speeds and may cause injury Unplug the unit from the power source when not using the unit for an extended period of time Otherwise it may cause fire and or electric shock caused by an electric leak Tips on dehumidifying Drain the water tank before use Drying laundry indoors Use the dehumidifier in a small enclos...

Page 6: ... Floating element 12 Front door The water tank may contain water residue at time of purchase This is from final product testing at the factory and is not due to a defect Control Panel COLD COLD lamp The lamp lights up if the room temperature drops below 15 C Activating LOW TEMP mode is recommended 10 It is impossible to remove the back panel because the two spots shown are fastened with two specia...

Page 7: ...This may be as often as once every 40 minutes The unit automatically shuts down and indicates with the lamp and sound that the water tank is full Empty the water tank Tank full lamp lights The unit beeps Airflow stops Lamp turns off After removing the water and replacing the tank the Tank full lamp will go off and then the unit will automatically return to operation mode When the Tank full lamp is...

Page 8: ...d it becomes cold causing water droplets to form on the surface of the cup The dehumidifier takes advantage of this phenomenon to remove moisture from the air 1The unit draws air from the room cools it with its cooling coil causing the moisture to transform into water droplets 2The water droplets fall into the water tank 3The dehumidified air is reheated by the heating coil and then discharged The...

Page 9: ... does not activate for 3 minutes when the unit is turned ON immediately after turning it OFF or plugging it into the power socket In order to protect the compressor When dehumidifying begins the operational noise increases Information Press If the room temperature falls below 15 C defrosting mode is activated once every 40 minutes for about 5 minutes causing water to drain to the tank The unit can...

Page 10: ...e such as carbon monoxide cannot be removed with these filters Humidity level Room temperature C 50 20 30 27 60 Room temperature is below 27 C the unit automatically sets the humidity level according to the temperature Room temperature is above 27 C the unit lowers the humidity level to 50 then activates the blower The dehumidifier is reactivated when humidity rises to 60 When temperature humidifi...

Page 11: ...pelled from inside the unit may smell due to odorants that were not caught by the filter dissolving in the water The OFF timer cannot be set during drying inside Information OFF Regular Regular operation operation Dehumidifier Air purifier Drying inside operation approx one hour Airflow Approx 30min Airflow stops compressor activates operating sound Compressor operates according to room temperatur...

Page 12: ...akage 12 Using the OFF Timer The OFF timer can be set for each 2 4 8 hours Set the timer when the power is switched on Removing Water from the Tank The unit automatically shuts down and lights the Tank full lamp when the tank approximately 4L is full Empty the tank 7 4 3 2 Press Press No Display Low mode One press 2 is displayed Each consecutive press displays the following setting 2 4 8 To cancel...

Page 13: ...e a minimum space of 20 cm behind the unit for attaching the hose Confirm that the hose does not show signs of deterioration such as cracks and clogging Inspect the hose every 2 weeks Insects or dirt blocking the hose may cause leakage resulting in malfunctions How to set up the drainage hose Correctly installed Incorrectly installed Necessary items Commercially available hose ID 15mm Long enough ...

Page 14: ...can damage the unit or the water tank which may result in leakage Water tank Main unit Wipe with a soft cloth Floating element Do not remove or dismantle Do not remove the louvre front door Pre filter 1 Remove the front panel and pre filter 2 Remove the air purifying filter 5 Attach the pre filter and front panel 4 Fit the air purifying filter 3 Clean the pre filter Remove grit with vacuum cleaner...

Page 15: ...g inside Performing drying inside to prevent mildew growth is recommended 2 Bundle power cord 3 Remove the drainage water Empty the water tank and wipe away any remaining drops of water 4 Clean the pre filter Remove grit with vacuum cleaner 5 Store the unit When you are sure that all parts of the unit are dry cover it with a cloth to keep it from dust Store the unit in an upright position in a pla...

Page 16: ...struction Check to see if the pre filter is clogged Clean according to the maintenance procedures Check to see if the unit is in AUTO The unit is automatically controlling the dehumidifier fan and standby times Check to see if the water tank is full Empty the water tank and return it to its original position Check to see if the water tank is inserted properly Adjust the position of the water tank ...

Page 17: ...s intermittently causing the sound to be heard occasionally The compressor does not activate after turning the unit off or for 3 minutes after plugging the unit into a power socket This is to protect the compressor from damage The heat converter heats rapidly causing a brief odour This is not a malfunction The moisture expelled from inside the unit may smell due to odorants that were not caught by...

Page 18: ... Telephone number Date of purchase Day Month Year This symbol mark is for EU countries only This symbol mark is according to the directive 2002 96 EC Article 10 Information for users and Annex IV Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at thei...

Reviews: