23
(2) LED monitor display
●
Start
Press the LAUNDRY switch and the DEHUMIDIFYING switch 4 times together when the
power is off. Turn on the power within 2 seconds.
●
Mode select Use the OFF timer switch to change the diagnostic modes (0 to 8).
●
End
Turn the power off.
--
Current
humidity
--
Room
temperature
indicator
Tube
temperature
indicator
1
2
4
5
8
7
6
3
0
LED all lit
Determined
frequency
Current
warm air
fan rank
Current
cool air
fan rank
Display example
0
1
2
3
4
5
6
7
8
Display item
Current
humidity
Room
temperature
indicator
Tube
temperature
indicator
—
—
Current
cool air
fan rank
Current
warm air
fan rank
Determined
frequency
LED all lit
Display section
example
48
28
12
00
00
02
02
50
88
Actual number
48%
28˚C
12˚C
—
—
Rank 2
Rank 2
50Hz
88
Note 1. Continue to 8 all lit if you cannot understand the current display number.
2. There is no display item for "3" and "4" in diagnostic mode.
e01̲mj̲e15bx̲S1-IT.indd 23
2010/06/10 17:30:15