![Mitsubishi Electric MEsoftstart/I00 Users, Installation & Instruction Manual Download Page 83](http://html.mh-extra.com/html/mitsubishi-electric/mesoftstart-i00/mesoftstart-i00_users-installation-and-instruction-manual_1811805083.webp)
83 MEsoftstart PC Interface Application
MEsoftstart PC App
This section describes how to install the MEsoftstart PC App on the user’s computer and how to use the interface to configure,
monitor and control the soft starter.
The MEsoftstart PC App is tested to run on the Windows 10 operating system.
Two versions of PC Application software are available: for the Pro variants and the Core variants - the difference between the
two is shown in the table below.
Table 19: MEsoftstart PC App differences for Pro and Core variants
MEsoftstart/I Pro variants
MEsoftstart/I Core variants
Configuration
The MEsoftstart/I Pro variants are full featured soft starters
that are highly configurable.
The PC Application for the Pro variants are designed to make
the complex configuration easy.
The MEsoftstart/I Core variants are easy to use with
configuration via potentiometers and switches.
The PC Application for the Core variants allows the user to
view the configuration (as set by the potentiometers and
switches) and set limited configurable parameters
(refer paragraph 5.2.1).
Monitoring
The PC Application for the Pro variants provides real-time
monitoring (while the motor is idle, starting, running and
stopping).
The PC Application for the Core variants provides monitoring
(while the motor is stopped or running but not while starting
and stopping)
Control
The Modbus link (PC Application, PLC or SCADA) allows Start, Stop and Reset control
Interface
The MEsoftstart PC application for Pro variants can be used
with Modbus RTU or Modbus TCP.
-
Modbus RTU interfaces on the RS485 RJ45 connector
on J2 or J3
-
Modbus TCP interfaces on the RJ45 Ethernet port on J1
The MEsoftstart PC application for Core variants is based on
Modbus RTU and interfaces on the RS485 RJ45 connector on
J1 or J2.
Cable
If the Modbus TCP interface is used, an Ethernet cable may
be used to connect the PC with the soft starter.
If Modbus RTU is used a special cable is needed that
converts the RS485 on the soft starter to a USB interface on
the laptop.
It is recommended to use the cable that is supplied to
ensure that the supported buffer size of the converter is
adequate.
Download the following version
-
MEsoftstart/I Pro
PC Interface Application
(supports RTU and TCP)
-
If using Modbus RTU, the
Driver for Modbus Interface
is
required
-
MEsoftstart/I Core
PC Interface Application
(supports only RTU)
-
Driver for Modbus Interface
Summary of Contents for MEsoftstart/I00
Page 15: ...15 Introduction Figure 3 Soft starter terminal and component identification ...
Page 37: ...37 Wiring Figure 23 Fitting protective guards over terminals ...
Page 77: ...77 Basic operation Pro models Figure 40 Understanding the data display ...
Page 97: ...97 MEsoftstart PC Interface Application Figure 60 MEsoftstart PC Application Fault screen ...
Page 119: ......