![Mitsubishi Electric MELSERVO MR-J4-B-LL Series Instruction Manual Download Page 42](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-j4-b-ll-series/melservo-mr-j4-b-ll-series_instruction-manual_239177042.webp)
2. SIGNALS AND WIRING
2 - 11
2.5 Interfaces
2.5.1 Internal connection diagram
POINT
For the CN8 connector, refer to section 13.3.1 of "MR-J4-_B_(-RJ) Servo
Amplifier Instruction Manual".
±10 V DC
±10 V DC
Approx.
6.2 k
Ω
Encoder
3
2
4
7
8
MR
MRR
MX
MXR
LG
PE
Servo motor
M
CN2
CN3
MO1
MO2
LG
4
14
1
Analog monitor
EM2
CN3
CN3
20
DICOM
5
10
CN3
3
13
9
DOCOM
(Note 1)
INP
Servo amplifier
USB
D+
GND
D-
2
3
5
CN5
MBR
DICOM
Forced stop 2
(Note 2)
RA
RA
Isolated
(Note 3)
24 V DC
(Note 3)
24 V DC
AD0
15
LG
11
AD1
19
AD2
12
Analog monitor input 1
± 10 V
Analog monitor input 2
± 10 V
Pressure feedback
+ 10 V
(Note 2)
Note 1. The signal cannot be used in the speed control mode and the pressure control mode.
2. This diagram shows sink I/O interface. For source I/O interface, refer to section 2.5.3.
3. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
Summary of Contents for MELSERVO MR-J4-B-LL Series
Page 9: ...A 8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 20 MEMO ...
Page 63: ...3 PARAMETERS 3 18 MEMO ...
Page 71: ...4 PRESSURE LOOP GAIN ADJUSTMENT 4 8 MEMO ...
Page 79: ...5 TROUBLESHOOTING 5 8 MEMO ...