100
13 Profile Position Mode Objects
13.8 [Profile deceleration (Obj. 6084h)]
13.8
[Profile deceleration (Obj. 6084h)]
[Profile deceleration (Obj. 6084h: 00h)]
Description
Set the deceleration time constant or the deceleration used in the profile position mode (pp) and the profile velocity mode (pv).
The description of the object varies as shown in the table below depending on [Pr. PT01.1 Speed/acceleration/deceleration
unit selection]. When [Pr. PT01.1] is set to "0", set the time required for the servo motor to reach the rated speed. The value
that can be set varies for each control mode.
*1 When "0" is set, the servo motor decelerates in accordance with the setting value of [Pr. PT50].
13.9
[Quick stop deceleration (Obj. 6085h)]
[Quick stop deceleration (Obj. 6085h: 00h)]
Description
Set the deceleration time constant or deceleration for the Quick stop function. When [Pr. PT01.1] is set to "0", set the time
required for the servo motor to stop from the rated speed.
The description of the object varies as shown in the table below depending on [Pr. PT01.1 Speed/acceleration/deceleration
unit selection].
*1 When the setting value of this object is "0", the deceleration time constant is 100 ms.
*2 When "0" is set, the servo motor decelerates in accordance with the setting value of [Pr. PC24].
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RW
RXMAP
Refer to the
following.
Refer to the
following.
acc units
Possible
Refer to the
following.
[Pr. PT01.1]
Default
Range
Units
Parameter
0 (encoder unit)
100
pp: 0 to 20000
pv: 0 to 50000
ms
[Pr. PT50]
1 (command unit)
0
0 to 4294967295
pulse/s
2
[Pr. PV07]
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RW
RXMAP
Refer to the
following.
Refer to the
following.
acc units
Possible
Refer to the
following.
[Pr. PT01.1]
Default
Range
Units
Parameter
0 (encoder unit)
100
0 to 20000
ms
[Pr. PC24]
1 (command unit)
0
0 to 4294967295
pulse/s
2
[Pr. PV09]