656
7 APPLICATION INSTRUCTIONS
7.8 String Processing Instructions
Processing details
• These instructions convert the digit at each place in hexadecimal notation of the 32-bit binary data specified by (s) to the
ASCII code, and store the converted data in the device number specified by (d) and later.
• The format of the decimal ASCII data to be stored in (d) depends on the status of SM705 (Number of conversion digits
selection).
*1 For the firmware version of the CPU module supporting SM705, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Application)
A CPU module which does not support SM705 operates in the same way as SM705 is off even if it is turned on.
■
Operation overview
The following figure shows the operation when SM705 (Number of conversion digits selection) is off and on.
Ex.
When the DBINHA(P) instruction is executed with a 32-bit binary data "000ABCDEH" stored in (s)
• When SM705 is off, the number of digits is fixed. Eight digits of "000ABCDE" are converted into ASCII data and stored.
• When SM705 is on, data is left-justified. The effective digits "000ABCDE" with the leading "0"s omitted ("ABCDE") are
converted into ASCII data and stored, and 00H is stored in the end.
Status of SM705
Storage format of (d)
Reference
OFF
Data is stored in a fixed number of digits (8 digits)
Page 657 Operation of when SM705 (Number of
conversion digits selection) is off
ON
Each digit is stored left-justified depending on the value of (s).
Page 657 Operation of when SM705 (Number of
conversion digits selection) is on
b31
b0
∙∙∙
(s)
DBINHA(P)
SM705: OFF
b15
b0
∙∙∙
30H
30H
(d)+0
0
D
C
A
0
0
41H
30H
(d)+1
43H
42H
(d)+2
45H
44H
(d)+3
00H
45H
(d)+2
(d)+3
E
B
A
NULL
D
C
B
E
b15
b0
∙∙∙
42H
41H
(d)+0
44H
43H
(d)+1
SM705: ON
000ABCDE
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......