7 CONTROL SUB FUNCTIONS
7.9 Other Functions
277
7
7.9
Other Functions
As other functions, Skip function, M code output function, Teaching function, Command in-position function, Acceleration/
deceleration processing function, Deceleration start flag function, During uncompleted OPR operation setting function, and
Interrupt function. Each function is executed by setting parameters or creating and writing a program.
Skip function
Skip function is used to perform the deceleration stop on the positioning data No. executed when Skip signal was input, and to
execute the next positioning data No.
This function uses the positioning data for which Continuous positioning control or Continuous path control is set in [Da.1]
Operation pattern during positioning.
Relation between the skip function and various controls
The following table shows the relation between Skip function and various controls.
: Set as required,
: Setting not possible
Control details
The following figure shows the operation of the skip function.
Control type
Skip function
Skip operation applicability
OPR control
Machine OPR control
Skip operation not possible
Fast OPR control
Major positioning control
Position control
1-axis linear control
Skip operation possible
2-/3-/4-axis linear
interpolation control
1-axis fixed-feed control
2-/3-/4-axis fixed-feed
control
2-axis circular
interpolation control
3-axis helical
interpolation control
1-/2-/3-/4-axis speed control
Skip operation not possible
Speed-position switching control
Skip operation possible
Position-speed switching control
Skip operation not possible
Other controls
Current value change
Skip operation possible
JUMP instruction, NOP
instruction
LOOP to LEND
Skip operation not possible
Manual control
JOG operation, Inching operation
Skip operation not possible
Manual pulse generator operation
V
ON
OFF
OFF
OFF
OFF
ON
ON
ON
t
BUSY signal
[XC, XD, XE, XF]
Deceleration
by Skip signal
Start of the next
positioning
Positioning
Positioning start signal
[Y10, Y11, Y12, Y13]
Positioning complete signal
[X14, X15, X16, X17]
Skip signal
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......