4 ADVANCED POSITIONING CONTROL
4.3 Setting the Block Start Data
159
4
Block start (normal start)
In Block start (normal start), the positioning data groups of a block are continuously executed in a set sequence starting from
the positioning data set in [Da.12] Start data No. by one start.
The following shows setting examples and a control example in which Block start data and Positioning data are set as shown
in the setting examples.
Setting example
■
Block start data settings
■
Positioning data settings
*1 1 block is defined as all the data continuing from the positioning data in which Continuous positioning control or Continuous path control
is set in [Da.1] Operation pattern to the positioning data in which Independent positioning control (Positioning complete) is set.
Axis 1 block start data
[Da.11] Shape
[Da.12] Start data No.
[Da.13] Special start
instruction
[Da.14] Parameter
1st point
1: Continue
1
0: Block start
2nd point
1: Continue
2
0: Block start
3rd point
1: Continue
5
0: Block start
4th point
1: Continue
10
0: Block start
5th point
0: End
15
0: Block start
Axis 1 positioning data
No.
[Da.1] Operation pattern
1
00: Positioning complete
2
11: Continuous path control
1 block
3
01: Continuous positioning
control
4
00: Positioning complete
5
11: Continuous path control
1 block
6
00: Positioning complete
10
00: Positioning complete
15
00: Positioning complete
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......