4 ADVANCED POSITIONING CONTROL
4.3 Setting the Block Start Data
4.3
Setting the Block Start Data
Relation between various controls and block start data
Block start data must be set to perform Advanced positioning control.
The setting requirements and details of each block start data item to be set differ according to the setting of [Da.13] Special
start instruction.
The following table shows the setting items of Block start data prepared for various control systems. For details on Condition
data with which the control execution is judged, refer to Setting the Condition Data on page 316. (The settings of Block start
data in this section are assumed to be performed using an engineering tool.)
: Set either of the two setting items.
: Setting not possible
: Setting not required (The set value is ignored. Set the value within the setting range, such as the initial value.)
*1 NEXT start instruction is used in combination with Repeated start (FOR loop) and Repeated start (FOR condition). The control using
only NEXT start instruction will not be performed.
*2 If End is set for the repeated start, the operation that is the same as the one of the block start (normal start) will be performed.
Setting Block start data using an engineering tool is recommended. To perform the setting using programs,
many programs and devices are required. The execution becomes complicated, and the scan times will
increase.
Setting items for block
start data
Block start
(normal start)
Condition
start
Wait start
Simultaneous
start
Repeated
start (FOR
loop)
Repeated
start (FOR
condition)
NEXT
start
[Da.11]
Shape
0: End
1: Continue
[Da.12]
Start data No.
1 to 600
[Da.13]
Special start
instruction
0
1
2
3
4
5
6
[Da.14]
Parameter
Condition data No.
No. of repetitions
Condition data
No.
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......