720
8 APPLICATION INSTRUCTION
8.26 Module Access Instruction
Reading 1-word/2-word data from another module
FROM(P), DFROM(P)
• FROM(P)
These instructions read (n) words of data from the buffer memory specified by (s) in intelligent function module specified by
(U/H), and store the data to the device specified by (d) and later (d).
• DFROM(P)
These instructions read the (n)
2 words of data from the buffer memory specified by (s) intelligent function module specified
by (U/H), and store the data to the device specified by (d) and later.
Setting data
■
Descriptions, ranges, and data types
*1 In the case of the ST language and the FBD/LD language, U/H displays as UnHn.
■
Applicable devices
*1 Only the DFROM(P) instruction can be used.
Ladder diagram
Structured text
ENO:=FROM(EN,UnHn,s,n,d);
ENO:=FROMP(EN,UnHn,s,n,d);
ENO:=DFROM(EN,UnHn,s,n,d);
ENO:=DFROMP(EN,UnHn,s,n,d);
FBD/LD
Operand
Description
Range
Data type
Data type (label)
(U/H)
Unit number
H1 to H10
16-bit unsigned binary
ANY16
(s)
Start address of the buffer memory where the read-target data is
stored
0 to 65535
16-bit unsigned binary
ANY16
(d)
FROM(P)
Head device number for storing the read data
16-bit signed binary
ANY16
DFROM(P)
32-bit signed binary
ANY32
(n)
Number of read data
1 to 65535
16-bit unsigned binary
ANY16
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
(U)
X, Y, M, L, SM,
F, B, SB, S
T, ST, C, D, W,
SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(U/H)
(s)
(d)
(n)
(U/H) (s)
(d)
(n)
EN
ENO
d
UnHn
s
n
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......