background image

5

Remote controller

How to set the batteries and the current
time

1

Remove the front lid and insert batteries.
Then reattach the front lid.

Insert the minus pole of the batteries first.
Check if the polarity of the batteries is correct.

2

Press the RESET button.

If the RESET button is not pressed, the remote con-
troller may not operate correctly.

3

Press the CLOCK set button.

4

Press the 

HR.

 and 

MIN.

 buttons (TIME SET

buttons) to set the current time.

Each time the 

HR.

 button is pressed, the set time

increases by 1 hour, and each time the 

MIN.

 button

is pressed, the set time increases by 1 minute.

5

Press the CLOCK set button again and close
the front lid.

Press using a
thin stick.

Press using a
thin stick.

Insert the minus pole
of the batteries first.

Remote controller
holder

1

Press the EMERGENCY OPERATION switch.

Each time the EMERGENCY OPERATION switch is
pressed, the unit will operate in order of EMER-
GENCY COOL MODE, EMERGENCY HEAT MODE
and STOP MODE.
However, when the EMERGENCY OPERATION
switch is once pressed, the unit will operate in test
run for 30 minutes and then the operation mode
shifts to EMERGENCY MODE.

Details of EMERGENCY MODE are as shown be-
low. However, the temperature control does not
work for 30 minutes in test run and the unit is set
to continuous operation. The fan speed is set to
High in test run and shifts to Medium after 30 min-
utes.

Operation mode

COOL

HEAT

Set temperature

24°C

24°C

Fan speed

Medium

Medium

Horizontal vane

Auto

Auto

The operation mode is indicated by the Operation
Indicator lamp on the indoor unit as following fig-
ure.

Operation Indicator lamp

When the remote controller cannot be used (emergency operation)

When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation
can be done using the EMERGENCY OPERATION switch.

2

To stop the emergency operation, press the
EMERGENCY OPERATION switch once (in
case of EMERGENCY HEAT MODE) or twice
(in case of EMERGENCY COOL MODE).

Operation Indicator

Operation Indicator

Operation Indicator

EMERGENCY HEAT

EMERGENCY COOL

STOP

Handling of the remote controller

The range that the signal can reach is about 6 m when
the remote controller is pointed at the front of the in-
door unit.

When a button is pressed, one or two beeps will be
heard from the indoor unit. If no sound is heard, op-
erate again.

Use the remote controller carefully.
If it is dropped, thrown or it gets wet, the remote con-
troller may not operate.

When installing on a wall, etc.

Install the remote controller holder in a position where
the signal reception sound (beep) can be heard from
the indoor unit when the 

ON/OFF

 button is pressed.

How to install/remove the remote controller

Installing :Insert the remote controller downward.
Removing :Pull it up.

Dry-cell batteries

 Reference for replacing batteries

Replace the batteries with new AAA alkaline batteries
in the following cases:

·

When the indoor unit does not respond to the remote
control signal.

·

When the display on the remote controller becomes
dim.

·

When a button of the remote controller is pressed, all
displays appear on the screen, and then disappear
immediately.

Do not use manganese batteries. The remote controller
could malfunction.

The service life of an alkaline battery is about 1 year.
However, a battery whose time limit is approaching
may be exhausted soon. The recommended usable
time limit is indicated (month/year) on the bottom of
the battery.

To prevent liquid leakage, take out all batteries when
the remote controller is not going to be used for a
long time.

 CAUTION:

If liquid from the batteries gets onto your skin or
clothes, wash it well with clean water.
If liquid from the batteries gets into your eyes, wash
them well with clean water and consult a doctor at
once.

Do not use rechargeable batteries.

Replace the 2 batteries with new ones of the same
type.

Dispose of exhausted batteries in the correct man-
ner.

PREPARATION BEFORE OPERATION

FAN

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

RESET CLOCK

I FEEL

COOL

DRY

AUTO

HEAT

Summary of Contents for MCFZ-A12WV

Page 1: ...i utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utilização ...

Page 2: ...tc with a high prob serious hazard depending on the conditions nual s written in the parentheses n etc door unit and do not put anything on them reful r supply plug from the power outlet ith the installation manual in a handy place for easy reference Do not use intermediate connection of the power supply cord or the extension cord and do not connect many devices to one AC outlet A fire or an elect...

Page 3: ...When installed on the ceiling Operation section When the air inlet grille is pulled forward Emergency operation switch ide temperature less than 10 C in the cooling mode operated at low outside temperature less than 10 C water con drop and wet or damage furniture etc poses reserve precision devices food animals plants and art objects uality etc are exposed to direct airflow tion itch it off and di...

Page 4: ...of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the remote controller just ...

Page 5: ... the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit If no sound is heard op erate again Use the remote controller carefully If it is dropped thrown or it gets wet the remote con troller may not operate When installing on a wall etc Install the remote controller holder in a position where the signal reception sound beep can be heard from the i...

Page 6: ...he MODE s changed COOL NOTE COOL When the room temperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set ...

Page 7: ...utton Each time this button is pressed the operation mode is changed in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button When the set temperature is to be changed Press the TOO WARM button to lower the temperature O...

Page 8: ... horizontal vane is moved manually it may ure is too low or when defrosting is being done the horizontal vane he AIR FLOW For the ceiling suspended unit Change the direction of the vertical vane manually nually r fingers may be caught When the air flow temperature is too low the air is blown out horizontally When the air flow temperature rises the air is blown out down wards AUTO AIR FLOW DIRECTIO...

Page 9: ...D FOR A LONG TIME When it is not going to be used for a long time 1 Perform the FAN operation for 3 or 4 hours to dry the inside of the air conditioner To perform FAN operation set the remote control ler to the highest temperature in the MANUAL COOL mode Refer to page 7 2 Turn off the breaker and or disconnect the power supply plug CAUTION Turn off the breaker and or disconnect the power sup ply p...

Page 10: ... the colour of the filter is not restored even if the filter is washed as the procedure shown on the left Cleaning the deodorizing filter or when the filter be comes black replace the filter with a new one Standard interval for filter replacement is about 1 year TER THE DEODORIZING FILTER Cleaning the deodorizing filter about once every 2 weeks 1 Remove the air filter and the deodorizing fil ter t...

Page 11: ...o Descrip TART FUNCTION on page Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor unit Air does not blow out soon in the heating operation The operation is stopped for about 10 minutes in the heating operation Hissing sound is so...

Page 12: ...FFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VN79A517H01 d for use in the residential onment Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Page 13: ......