11

BEFORE CONTACTING THE SERVICE REPRE-
SENTATIVE, CHECK THE FOLLOWING AGAIN

Question

The air conditioner cannot
be operated for about 3 min-
utes when restarted.

Cracking sound is heard.

The air from the indoor unit
smells strange.

The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to ro-
tate, it stops soon.

The sound of water flowing
is heard.

The sound as burbling is
heard.

The room cannot be cooled
sufficiently.

Mist is discharged from the
air outlet of the indoor unit.

Mechanical sound is heard
from the indoor unit.

Answer (not a malfunction)

• This protects the air conditioner according to in-

structions from the microprocessor. Please wait.

• This sound is generated by the expansion/con-

traction of the front panel, etc. due to change in
temperature.

• The air conditioner may suck in an odor adher-

ing to the wall, carpet, furniture, cloth, etc. and
blow it out with the air.

• When the outside temperature is low, the fan

may not operate to maintain sufficient cooling
capacity.

• This is the sound of refrigerant flowing inside

the air conditioner.

• This is the sound of condensed water flowing in

the heat exchanger.

• This is the sound of the heat exchanger defrost-

ing.

• This sound is heard when the outside air is ab-

sorbed from the drain hose in turning on the
range hood or the ventilation fan and that makes
water flowing in the drain hose spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside wind
is strong.

• When a ventilation fan or a gas cooker is used

in a room, the cooling load increases, resulting
in an insufficient cooling effect.

• When the outside temperature is high, the cool-

ing effect may not be sufficient.

• The cool air from the air conditioner rapidly cools

moisture in the air inside the room, and it turns
into mist.

• This is the switching sound in turning on/off the

fan or the compressor.

WHEN YOU THINK THAT TROUBLE HAS OCCURRED

Question

The air conditioner cannot
be operated.

The room cannot be cooled
or heated sufficiently.

The air from the indoor unit
smells strange.

The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the re-
mote control signal.

When a power failure oc-
curs.

Check points

• Is the breaker turned on?
• Is the fuse blown?
• Is the ON timer set? (Page 9)

• Is the temperature setting correct? (Page 7)
• Is the filter clean? (Page 10)
• Are there any obstacles blocking the air inlet or

outlet of the indoor or outdoor unit?

• Is a window or door open?

• Is the filter clean? (Page 10)

• Are the batteries exhausted? (Page 5)
• Is the polarity (+, -) of the batteries correct?

(Page 5)

• Are any buttons on the remote controller of other

electric appliances being pressed?

• Does the air conditioner start operating again?

If the air conditioner had operated before the
power failure, as these models are equipped with
an auto restart function, the air conditioner
should start operating again. (Refer to Descrip-
tion of “AUTO RESTART FUNCTION” on page
6.)

Question

The air flow direction
changes during operation.
The direction of the hori-
zontal vane cannot be ad-
justed with the remote con-
troller.

Water leaks from the out-
door unit.

White smoke is discharged
from the outdoor unit.

Air does not blow out soon
in the heating operation.

The operation is stopped
for about 10 minutes in the
heating operation.

Hissing sound is some-
times heard.

The room cannot be heated
sufficiently.

The air conditioner starts
the operation only with the
main power turned on,
though you do not operate
the unit with the remote
controller.

Answer (not a malfunction)

• When the air conditioner is operated in COOL

or DRY mode, if the operation continues with air
blowing down for 1 hour, the direction of the air
flow is automatically set to position 1 to prevent
condensed water from dropping.

• In the heating operation, if the air flow tempera-

ture is too low or when defrosting is being done,
the horizontal vane position is automatically set
to position 1.

• During COOL and DRY operations, pipe or pipe

connecting sections are cooled and this causes
water to condense.

• In the heating operation, the defrosting opera-

tion makes water frozen on the outdoor unit melt
and drip down.

• In the heating operation, water condensed on

the heat exchanger drips down.

• In the heating operation, vapor generated by the

defrosting operation looks like white smoke.

• Please wait as the air conditioner is preparing

to blow out warm air.

• Defrosting of the outdoor unit is being done (De-

frosting operation).
Since this is completed in 10 minutes, please
wait. (When the external temperature is too low
and humidity is too high, frost is formed.)

• This is the sound when the flow of refrigerant

inside the air conditioner is switched.

• When the outside temperature is low, the heat-

ing effect may not be sufficient.

• These models are equipped with an auto restart

function. When the main power is turned off with-
out stopping the air conditioner with the remote
controller and is turned on again, the air condi-
tioner will start operation automatically in the
same mode as the one set with the remote con-
troller just before the shutoff of the main power.

Even if the above items are checked, when the air conditioner does not
recover from the trouble, stop using the air conditioner and consult your
dealer.

In the following cases, stop using the air conditioner and consult your dealer.

When water leaks or drops from the indoor unit.

When the left operation indicator lamp blinks.

When the breaker trips frequently.

The remote control signal may not be received in a room where an electronic
ON/OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.

Operation of the air conditioner may interfere with radio or TV reception in
areas where the reception is weak. An amplifier may be required for the af-
fected device.

When thunder is heard, stop operation and disconnect the power supply plug
and/or turn off the breaker. Otherwise, the electrical parts may be damaged.

Summary of Contents for MCFZ-A12WV

Page 1: ...i utenti Per utilizzare correttamente quest unità leggere questo libretto d istruzioni atten tamente e per intero π π Àƒ π È ÙÔÓ ÂÏ ÙË È Ó ÚËÛÈÌÔ ÔÈ ÛÂÙ ٠ÙËÓ ÌÔÓ ÛˆÛÙ Î È Ì ÛÊ ÏÂÈ Â Èˆı Ù fiÙÈ ÂÙÂ È ÛÂÈ Ùfi ÙÔ ÂÁ ÂÈÚ ÈÔ Ô ËÁÈÒÓ ÚÈÓ fi ÙËÓ Ú ÛË INSTRUÇÕES DE OPERAÇÃO Para os clientes Para utilizar esta unidade correctamente certifique se de que lê estas instruções de operação antes da utilização ...

Page 2: ...tc with a high prob serious hazard depending on the conditions nual s written in the parentheses n etc door unit and do not put anything on them reful r supply plug from the power outlet ith the installation manual in a handy place for easy reference Do not use intermediate connection of the power supply cord or the extension cord and do not connect many devices to one AC outlet A fire or an elect...

Page 3: ...When installed on the ceiling Operation section When the air inlet grille is pulled forward Emergency operation switch ide temperature less than 10 C in the cooling mode operated at low outside temperature less than 10 C water con drop and wet or damage furniture etc poses reserve precision devices food animals plants and art objects uality etc are exposed to direct airflow tion itch it off and di...

Page 4: ...of the unit needs to be changed Auto restart function is When the indoor unit is controlled with the remote controller the operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to start operating in the same mode as the one set with the remote controller just ...

Page 5: ... the front of the in door unit When a button is pressed one or two beeps will be heard from the indoor unit If no sound is heard op erate again Use the remote controller carefully If it is dropped thrown or it gets wet the remote con troller may not operate When installing on a wall etc Install the remote controller holder in a position where the signal reception sound beep can be heard from the i...

Page 6: ...he MODE s changed COOL NOTE COOL When the room temperature is 2 C higher than the set temperature the set temperature may not be changed since the air conditioner is operating to reach the target set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than the set ...

Page 7: ...utton Each time this button is pressed the operation mode is changed in sequence I FEEL AUTO COOL DRY HEAT To stop operation Press the ON OFF button After the operation mode is set once the operation starts in the same mode as the one set previously from the next time by simply pressing the ON OFF button When the set temperature is to be changed Press the TOO WARM button to lower the temperature O...

Page 8: ... horizontal vane is moved manually it may ure is too low or when defrosting is being done the horizontal vane he AIR FLOW For the ceiling suspended unit Change the direction of the vertical vane manually nually r fingers may be caught When the air flow temperature is too low the air is blown out horizontally When the air flow temperature rises the air is blown out down wards AUTO AIR FLOW DIRECTIO...

Page 9: ...D FOR A LONG TIME When it is not going to be used for a long time 1 Perform the FAN operation for 3 or 4 hours to dry the inside of the air conditioner To perform FAN operation set the remote control ler to the highest temperature in the MANUAL COOL mode Refer to page 7 2 Turn off the breaker and or disconnect the power supply plug CAUTION Turn off the breaker and or disconnect the power sup ply p...

Page 10: ... the colour of the filter is not restored even if the filter is washed as the procedure shown on the left Cleaning the deodorizing filter or when the filter be comes black replace the filter with a new one Standard interval for filter replacement is about 1 year TER THE DEODORIZING FILTER Cleaning the deodorizing filter about once every 2 weeks 1 Remove the air filter and the deodorizing fil ter t...

Page 11: ...o Descrip TART FUNCTION on page Question The air flow direction changes during operation The direction of the hori zontal vane cannot be ad justed with the remote con troller Water leaks from the out door unit White smoke is discharged from the outdoor unit Air does not blow out soon in the heating operation The operation is stopped for about 10 minutes in the heating operation Hissing sound is so...

Page 12: ...FFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VN79A517H01 d for use in the residential onment Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC ...

Page 13: ......

Reviews: