17
─
Assembly precaution
Insert the maint. cover into the groove of the base. (Indicated by
)
2
Remove the fix plate.
Maint. cover
(2) Light receiving circuit board (JT-30S1R)
1
Unscrew the clamping screws, and remove the maintenance (maint.)
cover.
(Two special (spl) screws 4 x 16, indicated by
)
Maint. cover
12. Overhauling procedures
Work precautions
• Before replacing parts, follow the instructions described in the troubleshooting.
• When servicing, always take care to keep proper footing.
• Before starting the service, always unplug the power cord from the outlet, or turn off the earth leakage
breaker when no power cord plug is provided. Sufficient care must be taken to avoid electric shock or injury.
• Make sure to connect the power supply wires correctly.
• After completing repairs, check that the unit operates properly.
Always wear gloves when servicing.
(1) Turn off the power supply.
1
Stop the operation.
2
Turn off the earth leakage breaker on the distribution board.
Fix plate
Assembly precautions
• Run the lead wires through the groove of the maint. cover.
(Indicated by
)
• Take care not to pinch the lead wires.