2
Remove the terminal cover clamping screw.
(One PTT screw 4 x 8, indicated by
O
)
3
Remove the grounding wire clamping screws.
(Two PTT screws with the lock washer 4 x 8 (BS), indicated by
)
4
Remove the clamping screws for the control circuit board, cord
clips and line filter.
(Five PTT screws 4 x 16, indicated by
Q
)
5
Remove the cord band. (indicated by
)
6
Take out the control circuit board, and remove the board
cover. (Indicated by
O
)
7
Disconnect the lead wires from the control circuit board, and
remove the cord bushes. (Indicated by
O
)
Assembly precautions
• Remove the terminal cover before removing the control
circuit board.
• Be sure to use the lock washers when installing the
grounding wires.
Assembly precautions
• Connect the lead wires referring to the printing on the
control circuit board.
• Use the cord bushes with the smaller hole diameter shown
in the upper part of the photograph.
(4) Control circuit board
1
Pull out the drain tank and remove the front panel clamping
screws. (Two special screws 4 x 16, indicated by
O
)
Heater grounding wire (Green)
Circuit grounding wire (Black)
Summary of Contents for JT-SB216ESH-DG-CE
Page 9: ... 9 JT SB216ESH W CE JT SB216ESH DG CE 7 Electrical wiring diagram ...
Page 11: ... 12 2 Sub circuit JT 24S ...
Page 35: ...9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 6 7 8 36 5 5 5 5 7 7 JT SB216ESH W CE ...
Page 41: ...101 102 103 104 105 106 91 92 93 94 95 96 97 98 99 100 42 49 93 5 77 5 99 JT SB216ESH W CE ...
Page 45: ... 46 141 142 143 144 145 JT SB216ESH W CE ...
Page 47: ...9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 48 5 5 5 5 7 7 JT SB216ESH DG CE ...
Page 53: ...101 102 103 104 105 106 91 92 93 94 95 96 97 98 99 100 54 49 93 5 77 5 99 JT SB216ESH DG CE ...
Page 57: ... 58 141 142 143 144 145 JT SB216ESH DG CE ...