Maintenance - Continuation

Turning the sensor off before maintenance

1

Cleaning the unit exterior and hand drying area

2

1

 Pull the tab, open the front cover and turn the 

sensor switch "OFF".

  The sensor light "OFF" is lit.
  Refer to "How to open/close the front cover" on page 4.

2

 Wipe the unit exterior, the inside of the front 

cover, and the hand drying area with a damp 
piece of cloth.

  When it is unclean, wipe it with a piece of damp cloth 

that has been soaked in neutral detergent, thoroughly 
remove the remaining neutral detergent and wipe it with 
a piece of dry cloth.

  Clean the sensor area.

 The sensor may lose its sensitivity and malfunction if 

the transparent surface inside the hand drying area 
is covered with a white-colored substance. Please 
clean it once a week.

3

 Clean the dust off of the hook of the 

front cover with a commercially available 
toothbrush or cotton swab.

NOTE

  The front cover is designed to come off in order to 

prevent damage if it is opened too wide.
If it comes off, please reattach it while referring to "Precautions 
for when opening/closing the front cover" (Page 4).

4

 Turn the sensor switch "ON" and close the front 

cover so that there is no gap and push the tab.

  The sensor light "ON" is lit.

Exterior

Nozzle

Sensor

Hand drying area

Panel hook of the unit

Hook of the 
front cover

Hook of the front cover

Cotton swab, 
toothbrush, etc.

Cotton swab, 
toothbrush, etc.

Panel hook of 
the unit (both the 
upper and lower 
parts)

2

 Open the cover and press the sensor switch.

  The sensor light "OFF" is lit.

Sensor

light

Sensor

switch

1

 Pull the tab and open the front cover.

3

 Perform cleaning.

 Refer to 

2

 to 

4

 below.

4

 After cleaning, turn the sensor switch "ON".

  The sensor light "ON" is lit. 

Main unit

Front cover

Tab

Front cover

Open

Front cover

Open

  Water may enter the unit and cause short circuits, electric 

shocks or damage if the front cover is left open.

Caution

Pull

Sensor

light

Sensor

switch

Summary of Contents for Jet Towel JT-MC106G-W-NA

Page 1: ...purpose It has no sterilizing or disinfecting functions INDEX Safety Precautions 2 Names of Parts 3 How to use the unit 4 How to open close the front cover 4 Precautions for when opening closing the front cover 4 If not using for a long period 5 How to use the unit 5 Turning the heater on 6 Maintenance 7 Precautions for when opening closing the front cover 7 Turning the sensor off before maintenan...

Page 2: ... 90 angle or more refer to Page 4 Important Follow instructions Wear gloves during maintenance work Not doing so may result in injuries Always use the unit with the drain tank air filter and front cover attached Any water entering the unit may cause short circuits electric shocks or damage If the unit stops working or if a malfunction occurs turn off the power switch and ground fault circuit inter...

Page 3: ...ight Front cover Nozzle Sensor Names of Parts Shaded areas in the figure indicate antibacterial material excluding outlet nozzle areas Inside the front cover Refer to How to open close the front cover on page 4 Please refer to Turning the heater on Page 6 while turning the heater on off Please refer to Turning the sensor off before maintenance Page 8 while turning the sensor on off ...

Page 4: ...ose the left side both the upper and lower parts Front cover Front cover Tab Main unit Front cover Handle Open Precautions for when opening closing the front cover If the front cover comes off please reattach it with the following procedures It is designed to come off in order to prevent damage if it is opened too wide 1 Press the bottom connecting part of the removed front cover into the bottom p...

Page 5: ...s on your hands This may damage the unit If not using for a long period How to use the unit About 9cm Hand drying area Hand detection area Nozzle Sensor Please use within the area above The hand detection area may differ depending on the environment Automatic Stop Function The power light flashes and the dryer stops automatically if the unit is used continually for more than 40 seconds To continue ...

Page 6: ... not feel warm when the room temperature is low 68 F 20 C or below Checking the settings The heater light and sensor light turn off after about 10 seconds after their settings are made to save energy To check the settings press either the heater or sensor switch Simple heater Softens the feeling of cold air If the room temperature is above 80 F 30 C the heater will stop working to prevent the temp...

Page 7: ...fectants cause damage to the unit NOTE When cleaning the unit use a neutral detergent pH 6 8 Please do not use plant based detergents as they may cause damage to plastic parts When using a chemical cloth be sure to follow the instructions carefully Factors such as rust may shorten the working life of the unit Damage to the unit caused by the use of prohibited agents such as solvents detergents and...

Page 8: ...vailable toothbrush or cotton swab NOTE The front cover is designed to come off in order to prevent damage if it is opened too wide If it comes off please reattach it while referring to Precautions for when opening closing the front cover Page 4 4 Turn the sensor switch ON and close the front cover so that there is no gap and push the tab The sensor light ON is lit Exterior Nozzle Sensor Hand dryi...

Page 9: ...fitted properly Dirt and dust may get into the unit and shorten its working life if the air filter is out of position 5 Turn the sensor switch ON and close the front cover so that there is no gap and push the tab The sensor light ON is lit 2 Remove the air filter 3 Clean the air filter Tap it lightly or vacuum off the dust Wipe with lukewarm or cold water if it is extremely unclean NOTE After washi...

Page 10: ...il they make clicking sounds and make sure that it is fitted properly Push the drain tank all the way into to the main unit and make sure that it is fitted properly 2 Remove the drain tank while keeping it upright Keep it upright when carrying it so that the drain water does not spill Caution If it is used after the full line has been exceeded please be careful of water spilling out of the overflo...

Page 11: ...he heater on Page 6 while turning the heater off The front cover is designed to come off in order to prevent damage to the main unit if it is opened too wide Please reattach it while referring to Precautions for when opening closing the front cover Pages 4 and 7 Are any lights in the display on Has a power blackout occurred Was the sensor switch turned on while your hands or an object was inside t...

Page 12: ...hand Specifications Working life of the motor heater The working life of the motor and heater is 7 years when used 200 times per day The working life may be shortened if the unit is used in a location where the power supply voltage is high or when the operation times per user are long No air blows as the motor dies There may be odors or noise when the motor dies but this does not indicate a malfun...

Reviews: