Mitsubishi Electric Got1000 GT1455-QTBDE General Description Manual Download Page 6

This manual confers no industrial property rights or any rights of any other 

kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation 

cannot be held responsible for any problems involving industrial property rights 

which may occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for 

compensation to:

(1) Damages caused by any cause found not to be the responsibility of     

Mitsubishi.

(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi 

products.

(3) Special damages and secondary damages whether foreseeable or not, 

compensation for accidents, and compensation for damages to products 

other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

*1 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal

display panel. It is impossible to completely avoid this symptom, as the
liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color. 
Please note that these dots appear due to its characteristic and are not
caused by product defect.

• Flickers and partial discoloration may be generated on the liquid crystal

display panel due to the display contents or the contrast adjustment.

However, please note that these phenomena appear due to its
characteristic and are not caused by product defect.

• There is a difference in the display brightness and the color tones between

liquid crystal display panels. When using multiple liquid crystal display
panels, please note that there is an individual difference between them.

• A crosstalk (shadow as an extension of the display) may appear on the

liquid crystal display panel. Please note that it appears due to its
characteristic.

• When the display section is seen from the outside of the display angle, the

display color seems like it has changed. Please note that it is due to its
characteristic.
Please note that the response time, brightness and color of the liquid

crystal display panel may vary depending on the usage environmental
temperature.
Especially in the low temperature environment, the display response
becomes slow due to the characteristics of the STN liquid crystal.
Please check the display response in advance for using this product.

• When the same screen is displayed for a long time, an incidental color or

partial discoloration is generated on the screen due to heat damage, and it
may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.



GT14 User's Manual

• Just after the GOT is powered off, sometimes an image lag or partial

discoloration is generated temporary. However they are caused by the
characteristic of the liquid crystal. (After powering off, they disappear within
a few minutes.)

*2 Gradation inversion is a characteristic of liquid crystal displays.

Please be forewarned that depending on the displayed color, the visualization
may be difficult even within the described view angle.

*3 Using the GOT Backlight OFF function can prolong the life of the backlight.

For details on the Backlight OFF function, refer to the following.



GT14 User's Manual

*4 The touch panel is analog resistive film-type. If you touch the panel

simultaneously in 2 points or more, the switch that is located around the center
of the touched point, if any, may operate. Do not touch the panel in 2 points or

more simultaneously. Do not press the GOT display section with a pointed
material as a pen or driver. Doing so can result in a damage or failure of the
display section. For the analog-resistive film type touch panels, normally the
adjustment is not required. However, the difference between a touched
position and the object position may occur as the period of use elapses. When
any difference between a touched position and the object position occurs,
execute the touch panel calibration. When any difference between a touched
position and the object position occurs, other object may be activated.
This may cause an unexpected operation due to incorrect output or
malfunction.

*5 ROM in which new data can be written without deleting the written data.
*6 Set the terminating resistor selector switch of the GOT in accordance with the

connection type when adopting GOT multidrop connection.
For details of GOT multidrop connection, refer to the following.



GOT1000 Series Connection Manual

*7 Compliant with IP67 when the USB environmental protection cover is

attached. Not compliant when a USB cable is connected. Note that this does
not guarantee all users' operation environment. The protection is not applied
when the interface environment protection cover is removed.
In addition, the product may not be used in environments under exposition of
oil or chemicals for a long period of time, or in environments filled with oil-mist.

Appearance

White stripe patterns may appear on the surface of the resin molded part of the product. Please note that these phenomena appear due to the characteristics of the material
used in the product and are not caused by product defect.

3.3 Power Supply Specifications

Built-in 
interface

RS-422/485

RS-422/485 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

: D-sub 9-pin (Female)

Application

: PLC communication

Terminating resistor : Open/110

/330

 (Switched by terminating resistor selector switch)

*6

                                   (At factory shipment: 330

)

RS-232

RS-232 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

: D-sub 9-pin (Male)

Application

: PLC communication, bar code reader, RFID connection, PC communication 

(Project data upload/download, OS installation, transparent function)

Ethernet
(Only in models equipped with
Ethernet interface)

Data transfer method: 100BASE-TX/10BASE-T, 1ch

Connector shape       : RJ-45 (Modular jack)

Application

: PLC communication, Gateway functions, PC communication 

(Project data upload/download, OS installation, FA transparent function)

USB

Host

USB (Full Speed 12Mbps), 1ch

Connector shape

: TYPE-A

Application

: Data transfer, data storage

Device

USB (Full Speed 12Mbps), 1ch
Connector shape

: Mini-B

Application

: PC communication (Project data upload/download, OS installation, FA transparent function)

SD card

In conformance to SD standard, 1ch
Applicable memory cards : SDHC memory card, SD memory card
Application

: Project data upload/download, OS installation, logging data storage

Buzzer output

Single tone (tone length adjustable)

Environmental protective structure

*7

Equivalent to IP67 (front section)

External dimensions

W164(6.46) 

 H135(5.32) 

 D55(2.17)[mm](inch)(Excluding USB environmental protective cover) (Horizontal format)

Panel cutting dimensions

W153 (6.03) 

 H121(4.77)[mm] (inch) (Horizontal format)

Weight

Approx.

 

0.7kg (Excluding mounting fixtures)

Compatible software package

GT Designer3 Version1.37P or later

GT Designer3 Version1.118Y or later

GT Designer3 Version1.37P or later

Item

Specifications

GT1455-QTBD(E)

GT1450-QMBD(E)

GT1450-QLBD(E)

Item

Specifications

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

Input power supply voltage

24VDC (+10% -15%), ripple voltage 200mV or less

Fuse (built-in, not exchangeable)

1.6A

*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure.

The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.

3.4 External Dimensions

4. Installation

4.1 Control Panel Inside Dimensions for Mounting GOT

Mount the GOT onto the control panel while considering the following control panel
inside dimensions. 

Applicable cable

Some cables may need to be longer than the specified dimensions when connecting
to the GOT. Therefore, consider the connector dimensions and bending radius of the
cable as well for installation.

4.2 Panel Cutting Dimensions

Make holes in the panel according to the dimensions list below.
Also, ensure 10mm spaces in upper and lower parts of the panel for mounting
fixtures.

Power consumption

7.68W (320mA/24VDC) or less

8.40W (350mA/24VDC) or less

At backlight off

6.72W (280mA/24VDC) or less

7.44W (310mA/24VDC) or less

Inrush current

30A or less (26.4V) 2ms

Permissible instantaneous power 
failure time

*1

Within 5ms

Noise immunity

Noise voltage: 1000Vp-p, Noise width: 1

s (by noise simulator of 30 to 100Hz noise frequency)

Dielectric withstand voltage

500VAC for 1 minute (across power supply terminals and earth)

Insulation resistance

10M

 or larger by insulation resistance tester (across power supply terminals and earth)

Applicable wire size

For power supply: 0.75[mm

2

] or more, For grounding: 2[mm

2

] or more

Applicable solderless terminal

Solderless terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A

Applicable tightening torque 
(Terminal block terminal screw)

0.5 to 0.8[N

m]

Item

Specifications

GT1455-QTBD, GT1450-QMBD, GT1450-QLBD

GT1455-QTBDE, GT1450-QMBDE, GT1450-QLBDE

164 (6.46")

22

(0.87")

120 (4.73")

22

(0.87")

120 (4.73")

152 (5.99")

135 

(5.32")

47 

(1.86")

(0.24")

55 

(2.17")

#4-40UNC
(inch screw type)

M2.6
(Metric screw type)

Panel thickness: 2 to 4mm

                           (0.07" to 0.15") or less

Unit: mm (inch)

23 (0.91")

10 

(0.4")

10 

(0.4")

120 

(4.73")

No

Name

1)

PLC connection cable/PC connection cable

120 (4.73")

140

 (5.52")

152 (5.99")

30 (1.19")

1)

Unit: mm (inch)

153

(

6.03"            

)

+

-

2

0

+

-

0.08"

0

121

(

4.77"            

)

+ -

2 0

+ -

0.08" 0

Unit: mm (inch)

10 (0.4") or more

Panel thickness: 2 to 4mm
(0.07" to 0.15" inch)

10 (0.4") or more

4.3 Mounting Position

When mounting the GOT, the clearances shown on the right must be left from a

structure or the other device.

*1 Vertical format....50 mm (1.97”) or more
*2 Vertical format....80 mm (3.14”) or more

4.4 Control Panel Inside Temperature and Mounting Angle

When mounting the main unit to a control panel or similar, set the display section

as shown below.

When the temperature inside the control panel is 40 to 55

C (Horizontal mount),

40 to 50

C (Vertical mount), the mounting angle should be in the range 60

 to

105

 degrees.

The GOT will be 

deteriorated earlier if it is 

used at the mounting angle 

other than the above. 

Therefore, the temperature 

inside the control panel 

should be within 40

C.

4.5 Installation Procedure

The GOT is designed to be embedded into a panel. Mount the GOT by following

the procedure below. For panel cutting dimensions, refer to Section 4.2. Note that

the panel thickness should be within 2 to 4mm.
1) Installing the packing

Install packing to the packing

installation groove on the back

panel of the GOT. 

W h i l e   r e f e r r i n g   t o   t h e   c r o s s

sectional view of the packing

shown right, push the thinner side

into the packing groove.

(Right drawing is the example of

lateral format.) 

2) Inserting into the panel face

Insert the GOT from the front side

of the panel.

3) Fixing the GOT

Engage the hook of the mounting

fitting (accessory) to the unit fixing

hole of the GOT and tighten the

screw until the GOT is fixed with

the mounting bolt (accessory).

The GOT will be fixed in 4 upper/

lower parts.

Tighten the mounting screw with

the specified torque.

(Failure to do so may distort the

p a n e l   a n d   m a k e   a   s u r f a c e

waviness on the protective sheet.)

4) A protection film is attached on

the display section of GOT prior to

shipment. Remove the film when

the installation is completed.

Installation

Environment

A,D

B

C

E

In the presence of 

radiated-noise or 

heat-generating 

equipment nearby

50 mm 

(1.97”)

or more

80 mm

(3.14”)

or more

*1

50 mm

(1.97”)

or more

*2

100 mm 

(3.93”)

or more

In the absence of

radiated-noise or 

heat-generating 

equipment nearby

20 mm 

(0.79”)

or more

20 mm 

(0.79”)

or more

20 mm

(0.79”)

or more

20 mm 

(0.79”)

or more

C

B

A

D

E

Panel thickness: 2 to 4mm
(0.07" to 0.15" inch)

GOT

back 

panel

GOT

display

section

Control 

panel,

etc.

105

°

60

°

Packing

Packing

Packing 

installation groove

Magnified

illustration

Packing cross

sectional view

Inserting

direction

Mounting hole

Magnified

illustration

Mounting

fitting

Mounting

screw

5. Wiring

5.1 Power Supply Wiring

Connect the power supply to the power terminals on the back panel of the GOT.

Use 0.75mm

2

 or thicker cables to avoid voltage drop and tighten the terminal screw

with the specified torque securely.

Carry out the independent grounding if possible.

If the independent grounding is impossible, carry out the shared grounding as

shown in fig.2) below.

Use the cable of 2mm

2

 or more for grounding.

Set the grounding point closer to the GOT to make the grounding cable short as

possible.

1)

Recommended terminal shape 

6. Maintenance and Inspection

The GOT does not include consumable components that will cause the shorten life.

However, note that battery life is 5 years and LCD life is 50,000 hours. The life of

backlight is 70,000 hours.

It is recommended to replace the battery periodically. (For the replacement of the liquid

crystal screen and backlight, please consult your nearest sales office or FA Center.)

Refer to the following for the daily inspection and the periodic inspection.



GT14 User’s Manual

6.1 Battery Replacement

The battery is used for backing up the clock data, alarm history, recipe data, time action

setting value, advanced alarm, advanced recipe, logging, hardcopy or SRAM user

area. Screen data is stored in the flash memory and data is retained even if the battery

is dead.

Battery model name

GT14



 is shipped with the following battery.

Battery replacement procedure
1) Turn the GOT power off.
2) Open the battery cover of the GOT.
3) Remove the old battery from the GOT.
4) Disconnect the old battery

connector and insert the new battery

connector within 30s.

5) Insert the new battery into the GOT

and close the battery cover.

6) Turn the GOT power on.
7) Check if the battery condition is normal

with the utility.

Refer to the following for the details of

battery status display.



GT14 User’s Manual

Applicable solderless terminal

RAV 1.25-3, V2-N3A and FV2-N3A

Product name

Model name

Battery

GT11-50BAT

-

+

PC and external

device connection

cables

Power supply terminal

24VDC

power supply

Grounding

(100

Ω

 or less)

GOT

GOT

GOT

Other

device

Other

device

Other

device

Grounding

(100

Ω

 or less)

Grounding

(100

Ω

 or less)

(1) Independent ground

...... Best condition

(2) Shared grounding

...... Good condition

(3) Common grounding

...... Not allowed

Terminal 

screw

Solderless 

terminal

Terminal 

screw

6.2mm 

or less

3.2

3.2

6.2mm 

or less

When wiring one cable to 

one terminal

When wiring two cables to 

one terminal

Solderless 

terminal

Battery cover

Connector

Connector

Battery cover

How to confirm production year and month

The production year and month of the battery built in the purchased GOT can be

confirmed by the production No. (S/N) marked on the GOT main unit.

The production date of the optional replacement battery can be confirmed by the lot

No. marked on the nameplate (label) affixed on the battery.

Battery life

Approximate battery life: 

5 years (ambient temperature: 25

C)

Battery replacement: In 4 to 5 years 

Approximate life is 5 years, but life may be shorter depending on the ambient

temperature, therefore, note that the battery must be replaced in 4 to 5 years. Make

sure to purchase a new battery as needed as it self-discharges.

Battery status can be confirmed on a GOT utility screen.

For details of battery status or how to output alarm, refer to the following:



GT14 User’s Manual

7. Notification of CE marking

The following products have shown compliance through

direct testing (to the identified standards) and design

analysis (forming a technical construction file) to the

European Directive for Electromagnetic Compatibility (2004/108/EC) when used as

directed by the appropriate documentation.

This product is designed for use in industrial applications.

- Type: Graphic Operation Terminal
- Models: GOT series

For more details please contact your local Mitsubishi Electric sales site.

For details of CE marking, refer to the following.



GT14 User's Manual

7.1 Notes regarding the use of GOT units

7.1.1

General notes on the use of communication cables

Any device which utilizes a data communication function is susceptible to the wider

effects of local EMC noise. Therefore, when installing any communication cables care

should always be taken with the routing and location of those cables. Optional ferrite

cores are recommended when the cable route is close to EMC noise sources like

welders, large motors, etc. All tests have been performed with original Mitsubishi

cables. For customer prepared cables, please refer to the manuals. 

7.1.2

General notes on power supply 

All units require an additional ferrite filter to be attached to the 24V DC power supply

cables. The filter should be attached in a similar manner as shown in the figure

opposite, i.e. the power cables are wrapped around the filter. However, as with all EMC

situations the more correctly applied precautions the better the system's

electromagnetic compatibility. The ferrite recommended is a TDK ZCAT3035-1330 or

similar (shown in Ex.2). The ferrite should be placed as near to the 24V DC terminals of

the all units as possible (which should be within 75mm of the GOT terminal).  

Note: The customer must evaluate conformance of the final produced unit with

the EMC directive. 

Standard

Remark

EN61131-2 : 2007

Programmable 
controllers 

- Equipment, 

requirements and tests

EMI

Compliance with all relevant aspects of the standard.
(Radiated Emissions)

EMS

Compliance with all relevant aspects of the standard.

(ESD,RF electromagnetic field, EFTB, Surge, RF

conducted disturbances and Power frequency magnetic
field)

GOT Unit

Existing Cables

User Made Cables

All units

Ex. GT01-C30R4-8P (as shown in EX.1)
A complete list of appropriate cables can be 

found in the GOT user's manual.

3rd party cables need to be
independently tested by the user

to demonstrate EMC compliance.

1

1

6 0 0 0 3

Example nameplate (manufacture's serial number 1160003)

7-digit

Control number

Month (example: Jun.), 1 to 9: Jan. to Sep.,

X: Oct., Y: Nov., Z: Dec.

Year (example: 2011) Last two digit of year

* Actual product 
  nameplate differs from 
  the shown on the left.

 

 

GT11-50BAT

LOT.116

Connector

LOT.

Model 

name

Name

plate

Year (example: 2011) 

Last two digit of year

Month 

(example: Jun.)

1 (Jan.) to 9 (Sep.), 

X (Oct.), Y (Nov.), Z (Dec.)

1

3-digit

6

1

F = Ferrite core

Ex. Tokin-ESD-R-17S or similar

Ex.1

Ex.2

Up to 75mm

24V DC

INPUT

+

-

TDK

100mm

250mm

140mm

GT01-C30R4-8P

Comes 

equipped

Optional

Optional

GOT

 units

Programmable controller

F

F

F

8. Certification of UL, cUL standards

Environmental rating

Front: Type 4X (indoor use only) 

Using GOT

GOT is for use on a flat surface  of  a Type 1 or Type 4X (indoor use only)

enclosure 

「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品
 本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表

所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 

26572规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/
T 26572规定的限量要求。

Referenced Standard: GB/T15969.2 
(Requirement of Chinese standardized law)

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

显示器
GOT

外壳

印刷基板

×

电缆

×

Summary of Contents for Got1000 GT1455-QTBDE

Page 1: ...uch panels normally the adjustment is not required However the difference between a touched position and the object position may occur as the period of use elapses When any difference between a touched position and the object position occurs execute the touch panel calibration When any difference between a touched position and the object position occurs other object may be activated This may cause...

Page 2: ...uch panels normally the adjustment is not required However the difference between a touched position and the object position may occur as the period of use elapses When any difference between a touched position and the object position occurs execute the touch panel calibration When any difference between a touched position and the object position occurs other object may be activated This may cause...

Page 3: ...5 QTBD GT1450 QMBD GT1450 QLBD GT1455 QTBDE GT1450 QMBDE GT1450 QLBDE 164 6 46 22 0 87 120 4 73 22 0 87 120 4 73 152 5 99 135 5 32 47 1 86 6 0 24 55 2 17 4 40UNC inch screw type M2 6 Metric screw type Panel thickness 2 to 4mm 0 07 to 0 15 or less Unit mm inch 23 0 91 10 0 4 10 0 4 120 4 73 No Name 1 PLC connection cable PC connection cable 120 4 73 140 5 52 152 5 99 30 1 19 1 Unit mm inch 153 6 03...

Page 4: ...5 QTBD GT1450 QMBD GT1450 QLBD GT1455 QTBDE GT1450 QMBDE GT1450 QLBDE 164 6 46 22 0 87 120 4 73 22 0 87 120 4 73 152 5 99 135 5 32 47 1 86 6 0 24 55 2 17 4 40UNC inch screw type M2 6 Metric screw type Panel thickness 2 to 4mm 0 07 to 0 15 or less Unit mm inch 23 0 91 10 0 4 10 0 4 120 4 73 No Name 1 PLC connection cable PC connection cable 120 4 73 140 5 52 152 5 99 30 1 19 1 Unit mm inch 153 6 03...

Page 5: ...uch panels normally the adjustment is not required However the difference between a touched position and the object position may occur as the period of use elapses When any difference between a touched position and the object position occurs execute the touch panel calibration When any difference between a touched position and the object position occurs other object may be activated This may cause...

Page 6: ...5 QTBD GT1450 QMBD GT1450 QLBD GT1455 QTBDE GT1450 QMBDE GT1450 QLBDE 164 6 46 22 0 87 120 4 73 22 0 87 120 4 73 152 5 99 135 5 32 47 1 86 6 0 24 55 2 17 4 40UNC inch screw type M2 6 Metric screw type Panel thickness 2 to 4mm 0 07 to 0 15 or less Unit mm inch 23 0 91 10 0 4 10 0 4 120 4 73 No Name 1 PLC connection cable PC connection cable 120 4 73 140 5 52 152 5 99 30 1 19 1 Unit mm inch 153 6 03...

Reviews: