14. CONNECTION TO PANASONIC SERVO AMPLIFIER
14.3 Connection Diagram
14.3 Connection Diagram
The following diagram shows the connection between the
GOT and the Servo amplifier.
14.3.1 RS-232 cable
Connection diagram
RS232 connection diagram 1)
*1
GT16/15: CD, GT14:NC, GT12:NC, GT11: NC
Precautions when preparing a cable
(1) Cable length
The length of the RS-232 cable must be 2m or less.
(2) GOT side connector
For the GOT side connector, refer to the following.
1.4.1 GOT connector specifications
(3) PANASONIC servo amplifier side connector
Use the connector compatible with the PANASONIC
servo amplifier.
For details, refer to the user's manual of the
PANASONIC servo amplifier.
14.3.2 RS-485 cable
Connection diagram
RS485 connection diagram 1)
RS485 connection diagram 2)
GOT side(9-pin)
PANASONIC servo amplifier side
CD/NC*
1
RD(RXD)
SD(TXD)
ER(DTR)
SG
DR(DSR)
RS(RTS)
CS(CTS)
-
1
2
3
4
5
6
7
8
9
1
3
5
2
4
6
7
8
TXD
RXD
G
RS485+
RS485-
GOT side
PANASONIC servo amplifier side
SDA1(TXD1+)
SDB1(TXD1-)
RDA1(RXD1+)
RDB1(RXD1-)
SDA2(TXD2+)
SDB2(TXD2-)
RDA2(RXD2+)
RDB2(RXD2-)
RSA(RTS+)
RSB(RTS-)
CSA(CTS+)
CSB(CTS-)
SG
NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Shell
7
8
1
2
3
4
5
6
RS485+
RS485-
TXD
G
RXD
GOT side
PANASONIC servo amplifier side
SDA1
SDB1
RDA1
RDB1
SDA2
SDB2
RDA2
RDB2
SG
FG
1
2
3
4
5
6
7
8
9
10
7
8
1
2
3
5
6
4
RS485+
RS485-
TXD
RXD
G
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......