8 - 16
8. CONNECTION TO JTEKT PLC
8.5 PLC Side Setting
8.5 PLC Side Setting
POINT
POINT
POINT
JTEKT PLC
For details of JTEKT PLCs, refer to the following
manuals.
JTEKT PLC user's manual
8.5.1
Connecting to PC3JG, PC3JD,
PC3JD-C, PC3JG-P, PC3J,
PC3JL, PC2J, PC2JS or
PC2JR
Communication settings
Make the communication settings using the PLC
peripheral device (PCwin).
*1
Adjust the settings with GOT settings.
*2
Avoid duplication of the station No. with any of the other
units.
*3
Make the settings referring to the following connection
diagram.
8.5.2
Connecting to PC2JC
Communication settings
Make the communication settings using each setting
switch.
For the detail settings, refer to the following manual.
JTEKT PLC user's manual
*1
Adjust the settings with GOT settings.
Settings by switch
Make the communication settings using each setting
switch.
(1) Setting of the station No.
Set the station No. between 00 and 37 (Octal).
(2) Transmission speed settings
(3) Settings of data length and stop bit length
Model name
Refer to
PLC CPU
PC3JG, PC3JG-P,
PC3JD, PC3JD-C,
PC3J, PC3JL, PC2J,
PC2JS, PC2JR
PC2JC
PC2J16P, PC2J16RR
RS-232/RS-422
interface converter
RS-232/RS-422
interface converter
Link unit
PC/CMP-LINK
2PORT-LINK
PC/CMP2-LINK
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Data bit
*1
8bits, 7bits
Parity bit
Even (fixed)
Stop bit
*1
1bit, 2bits
Station No.
*2
0 to 37 (Octal)
2-wire/4-wire type
*3
2-wire type or 4-wire type
Item
Set value
Transmission speed
*1
9600bps, 19200bps
Data bit
*1
8bits, 7bits
Stop bit
*1
1bit, 2bits
Station No.
*1
0 to 37 (Octal)
Switch name
Station number setting
SW3
Upper digit
SW4
Lower digit
Switch name
Switch position
Transmission
speed (bps)
SW2
1
19200
2
9600
Switch name
Setting item
Set value
Switch No.
2
1
SW5
Data bit
8bits
OFF
7bits
ON
Stop
bit length
2bits
OFF
1bit
ON
A
6
D
B
C
4
8
F
1
0
E
2
9
7
3
5
A
6
D
B
C
4
8
F
1
0
E
2
9
7
3
5
A
6
D
B
C
4
8
F
1
0
E
2
9
7
3
5
ST.NO.H
ST.NO.L
BAUDRA
P O W E R
E R R
A L M
R U N
R E S E T
S T A R T
W R E M
R O M
P C 2 J C C P U
I / F
1 s t .
2 n d .
3 r d .
/
/
/
/
B A T T E R Y
Exchanged
T E R M
.
.
.
Transmission speed
setting switch SW2
Station number switch
SW3, SW4
Data length,stop bit
length SW5
Summary of Contents for GOT 1000 Series
Page 2: ......
Page 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 78: ......
Page 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Page 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Page 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Page 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Page 432: ...REVISIONS 3 ...
Page 435: ......