Y05-005 Jul.2006(MEE)

Specifications subject to change without notice.

Single-phase unit

CONNECTION DIAGRAM

HIGH SPEED OPERATION

LOW SPEED OPERATION

FOR CONTROLLING A MULTIPLE NUMBER OF UNITS

Model GK-2509YS1,2512AS1
 

GK-3009AS1,3012AS1

 

GK-3506CS,3509CS,3512DS

POWER
SOURCE

INTERNAL WIRING

CONTROL SWITCH

ON/OFF

HIGH/LOW

TERMINAL

BLOCK

MOTOR

RELAY

7

5

1

3

8

WHITE

GREEN

LOW

HIGH

RED

RED

BLUE

WHITE

COMMON

POWER
SOURCE

ON

OFF

LOW

HIGH

COMMON

POWER
SOURCE

ON

ON

LOW

HIGH

COMMON

POWER
SOURCE

LOW

HIGH

COMMON

LOW

HIGH

COMMON

LOW

HIGH

COMMON

POWER
SOURCE

The opening for connecting the control switch is designed to accommodate a cabie with
a diameter of 1.6mm or 2.0mm only. (Therefore, a stranded cable cannot be connected.)

AIR CURTAIN

ON/OFF Switch

Operation lamp

FS-04SW1-E

HIGH/LOW Switch

LOW

HIGH

COMMON

AIR CURTAIN

LOW

HIGH

COMMON

1

3

4

2

1

3

0

Wiring

Three-phase unit

Connecting the FS-04SW1-E (For single-phase unit)

A Hidden Barrier

Giving Tangible Benefits

A I R   C U R T A I N

CONNECTION DIAGRAM
Model MK-5010T-E,5012T-E

POWER
SOURCE

INTERNAL WIRING

CONTROL SWITCH

ON/OFF

TERMINAL

BLOCK

MOTOR

MOTOR

GREEN

V

W

RED

BLACK

WHITE

U

POWER
SOURCE

V

W

U

V

W

U

V

W

U

FOR CONTROLLING A MULTIPLE NUMBER OF UNITS

AIR CURTAIN

HEAD OFFICE : TOKYO BLDG., 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

http://Global.MitsubishiElectric.com

GK/MK SERIES

MODEL

Summary of Contents for GK-2509YS

Page 1: ...ecting the control switch is designed to accommodate a cabie with a diameter of 1 6mm or 2 0mm only Therefore a stranded cable cannot be connected AIR CURTAIN ON OFF Switch Operation lamp FS 04SW1 E HIGH LOW Switch LOW HIGH COMMON AIR CURTAIN LOW HIGH COMMON 1 3 4 2 1 3 0 Wiring Three phase unit Connecting the FS 04SW1 E For single phase unit A Hidden Barrier Giving Tangible Benefits A I R C U R T...

Page 2: ...internally and externally ExtraFan is a major improvement over the Line Flow Fan The fan is driven by an energy efficient motor and costs even less to operate The use of Axial Fan ExtraFan makes it easier to maintain the unit and keep the air curtain in top condition at all times Moreover the improvements that have resulted from the change to the Axial Flow Fan from the Line Flow Fan mean that fan...

Page 3: ... comparatively low Economic benefits of installing an air curtain Savings are calculated using an appropriate heating load factor required to keep room temperature constant at 28ºC for a room measuring 66 4m2 in area Revising the Performance Records on Shut Outs Air Curtains Increased Cold Storage Efficiency and Shut Out Effect Insect Shut Out Test HEATING MODE Economic benefits of installing an a...

Page 4: ...um angle is indicated The above figure is posted based on the values calculated by applying the average blowout velocity In order to prevent insects from breaking into the room the air flow blown out from the air curtain must reach the attainment point at a velocity at least that indicated in the table below Choose an optimum model by consulting the figure posted on the page 11 denoting the averag...

Page 5: ...wind 4 Install the air curtain which is the same as or slightly wider than the width of the doorway 7 To run effectively the air curtain concurrently with ventilating fan s provide ventilating or air supply opening s to avoid negative pressure to occur inside the room Otherwise run the ventilating fan of a type concurrent feeding and discharging 5 Do not leave spacing between the air curtain and t...

Page 6: ...t A clean warehouse environment is therefore preserved Bowling Alleys Lounges The air curtain can invisibly shut out areas that do not require air conditioning For example there is no need to air condition the lane side of a bowling alley so the air curtain acts as an air conditioning zoning device The elimination of unnecessary air conditioning cuts down on costs without compromising on the provi...

Page 7: ...0 1 760 1 950 1 350 1 400 1 330 1 320 1 150 2 100 1 860 2 640 2 310 43 44 5 43 38 41 35 46 47 46 5 40 5 44 38 46 47 49 5 43 45 5 42 5 49 50 52 46 47 45 55 56 53 54 58 58 55 5 56 58 58 5 55 5 56 5 Starting Current A 0 43 0 62 0 86 1 05 1 53 0 93 2 53 1 55 3 02 1 84 10 5 13 3 11 0 14 0 15 5 22 0 28 5 Specifications may be subject to change without notice The GK 35 type might not be sold by the regio...

Page 8: ...80 3 120 2 380 2 700 64 5 66 5 61 0 64 0 66 0 68 5 63 0 66 0 67 5 70 0 64 5 67 5 Starting Current A 1 4 1 3 2 1 1 9 2 8 2 6 15 5 20 25 Specifications may be subject to change without notice Specifications MK type MK 5010T E MK 5012T E Model Power Frequency Hz Three phase 50 60Hz 380 440 380V Input W Current A Air velocity Max m sec Air volume m3 h Noise dB Weight kg Width of unit cm 101 8 126 336 ...

Reviews: