Mitsubishi Electric GK-2509YS Brochure & Specs Download Page 7

11

12

80

4-10

×

20

Mounting holes

75

A

C

Power supply in

200

15

15

130

25

190

105

20

153

35

70

B

Dimensions

GK-25,GK-30 type

GK-35 type

Remote-Control Switch

Model FS-04SW1-E

Single-phase, exposed type(240VAC, 10A), High/Low switching

CONNECTION
(The broken line area shall be wired by the customer)

Dimensions (unit: mm)

GK-2509YS1
GK-2512AS1
GK-3009AS1
GK-3012AS1

900

1,194

900

1,194

A

Model

750

1,044

750

1,044

B

5
6
5
6

C

Dimensions (unit: mm)

(unit: mm)

(unit: mm)

(unit: mm)

GK-3506CS
GK-3509CS
GK-3512DS

608
910

1,187

A

Model

308
610
887

B

-

210
487

C

3
5
6

D

4
8
8

E

Terminal

block

COMMON

LOW

HIGH

L

N

HIGH

LOW

COM

Power supply

φ

220V-240V

50/60Hz

Air Curtain

ON/OFF Switch

High/Low Switch

Operation lamp

FS-04SW1-E

(Bottom View)

12.2

20.4

6.5

Operation lamp

70

120

ON/OFF Switch

HIGH/LOW Switch

Power supply in

A

200

8

8

20

130

C

B

152

74

210

35

200

220

D

E-10

×

21

Mounting holes

Specifications

GK-2509YS1

GK-2512AS1

GK-3009AS1

GK-3012AS1

GK-3506CS

GK-3509CS

GK-3512DS

Model

Power

Fan speed

Single-phase,

50/60Hz

220-240/220V

Single-phase,

50Hz

220-240V

Input (W)

(50/60Hz)

Current (A)

(50/60Hz)

Air velocity

Max. (m/sec)

(50/60Hz)

Air volume (m

3

/h)

(50/60Hz)

Noise (dB)

(50/60Hz)

Weight

(kg)

Width
of unit

(cm)

90

119.4

90

119.4

60.8

91

118.7

54-61/63

52-59/54

76-83/84

67-78/71

90-105/102

76-87/84

107-125/125

95-109/104

116-135/-

93-102/-

191-223/-

155-170/-

227-267/-

187-206/-

High

Low

High

Low

High

Low

High

Low

High

Low

High

Low

High

Low

0.25-0.26/0.29

0.24-0.25/0.25

0.35-0.37/0.39

0.31-0.33/0.33

0.43-0.46/0.47

0.35-0.37/0.39

0.52-0.56/0.58

0.44-0.46/0.48

0.53-0.57/-

0.44-0.45/-

0.87-0.94/-

0.74-0.75/-

1.05-1.13/-

0.89-0.9/-

9.5/9.5

7/7

9.5/9.5

7/7

12/12

8/8

12/12

8/8

13.5/-

11/-

13.5/-

11/-

13.5/-

11/-

1,210-1,230/1,170

980-1,000/930

1,420-1,440/1,410

1,150-1,170/1,090

1,450-1,470/1,640

1,100-1,200/1,150

1,740-1,760/1,950

1,350-1,400/1,330

1,320/-

1,150/-

2,100/-

1,860/-

2,640/-

2,310/-

43-44.5/43

38-41/35

46-47/46.5

40.5-44/38

46-47/49.5

43-45.5/42.5

49-50/52

46-47/45

55-56/-

53-54/-

58-58/-

55.5-56/-

58-58.5/-

55.5-56.5/-

Starting Current

(A)

0.43

0.62

0.86

1.05

1.53

0.93

2.53

1.55

3.02

1.84

10.5

13.3

11.0

14.0

15.5

22.0

28.5

*Specifications may be subject to change without notice.
*The GK-35 type might not be sold by the region. Please acknowledge it.

Use conditions: The temperature should be between -10 and +45°C. The RH should be 
less than 90% at room temperature. Any condition outside of this range could result in 
burnout, deformed, malrotating or damaged parts.

Note

GK

Standard type

Extensive Range-22 Types to Suit a 
Variety of Applications

MODEL

Selection

-

GK-2509YS1

-

GK-2512AS1

-

GK-2509YS1

GK-2512AS1

-

GK-3009AS1

-

GK-3012AS1

-

GK-3009AS1

GK-3012AS1

GK-3506CS

GK-3509CS

-

-

GK-3512DS

GK-3506CS

GK-3509CS

GK-3512DS

GK-3506SA

GK-3509SA

GK-3512SA

-

-

MK-5010T

MK-5012T

-

-

-

GK-3506SA

GK-3509SA

GK-3512SA

Air

outlet

1m

Air-velocity distribution (m/s) and

standard shut-out distance (m)

Overall length of unit (cm)

Standard installation

Vertical installation

Applications

Stores and offices

General use

Factories, buildings, and warehouses

Refrigerating and freezing rooms

2m

3m

4m

5m

6m

60

90

100

120

60

90

120

GK-25

GK-30

GK-35

(Standard type)

MK-50

12-17

(7-9)

(5-8)

(4-6)

(3-5)

(2-4)

5m

(1-3)

7

5

4

3

2

1

10-14.5

(5-6)

(4-5)

(3-4)

(2.5-3.5)

3.5m

5

4

3

2.5

GK-35

(High-Power type)

11-16

(6-7)

(5-6)

(4-5)

(3-4)

3.5m

6

5

4

3

8-13

(4-4.5)

(3-4)

(2.5-3.5)

(1-2.5)

3m

4

3.5

2.5

1

7-9.5

(3-4)

(2-3)

2.5m

3

2

1.5

*The figure in     indicates an average velocity (m/s) measured at the given distance.
*The figure in parentheses indicates the maximum velocity (m/s) measured in each area of one(1) meter.
*The velocities in a free space, free from an effect of differences between outdoors and indoors in pressure, temperature, or ambient  wind, are measured and 

indicated. Therefore, the velocity in the vicinity of the floor may differ from those indicated in the figure.

Summary of Contents for GK-2509YS

Page 1: ...ecting the control switch is designed to accommodate a cabie with a diameter of 1 6mm or 2 0mm only Therefore a stranded cable cannot be connected AIR CURTAIN ON OFF Switch Operation lamp FS 04SW1 E HIGH LOW Switch LOW HIGH COMMON AIR CURTAIN LOW HIGH COMMON 1 3 4 2 1 3 0 Wiring Three phase unit Connecting the FS 04SW1 E For single phase unit A Hidden Barrier Giving Tangible Benefits A I R C U R T...

Page 2: ...internally and externally ExtraFan is a major improvement over the Line Flow Fan The fan is driven by an energy efficient motor and costs even less to operate The use of Axial Fan ExtraFan makes it easier to maintain the unit and keep the air curtain in top condition at all times Moreover the improvements that have resulted from the change to the Axial Flow Fan from the Line Flow Fan mean that fan...

Page 3: ... comparatively low Economic benefits of installing an air curtain Savings are calculated using an appropriate heating load factor required to keep room temperature constant at 28ºC for a room measuring 66 4m2 in area Revising the Performance Records on Shut Outs Air Curtains Increased Cold Storage Efficiency and Shut Out Effect Insect Shut Out Test HEATING MODE Economic benefits of installing an a...

Page 4: ...um angle is indicated The above figure is posted based on the values calculated by applying the average blowout velocity In order to prevent insects from breaking into the room the air flow blown out from the air curtain must reach the attainment point at a velocity at least that indicated in the table below Choose an optimum model by consulting the figure posted on the page 11 denoting the averag...

Page 5: ...wind 4 Install the air curtain which is the same as or slightly wider than the width of the doorway 7 To run effectively the air curtain concurrently with ventilating fan s provide ventilating or air supply opening s to avoid negative pressure to occur inside the room Otherwise run the ventilating fan of a type concurrent feeding and discharging 5 Do not leave spacing between the air curtain and t...

Page 6: ...t A clean warehouse environment is therefore preserved Bowling Alleys Lounges The air curtain can invisibly shut out areas that do not require air conditioning For example there is no need to air condition the lane side of a bowling alley so the air curtain acts as an air conditioning zoning device The elimination of unnecessary air conditioning cuts down on costs without compromising on the provi...

Page 7: ...0 1 760 1 950 1 350 1 400 1 330 1 320 1 150 2 100 1 860 2 640 2 310 43 44 5 43 38 41 35 46 47 46 5 40 5 44 38 46 47 49 5 43 45 5 42 5 49 50 52 46 47 45 55 56 53 54 58 58 55 5 56 58 58 5 55 5 56 5 Starting Current A 0 43 0 62 0 86 1 05 1 53 0 93 2 53 1 55 3 02 1 84 10 5 13 3 11 0 14 0 15 5 22 0 28 5 Specifications may be subject to change without notice The GK 35 type might not be sold by the regio...

Page 8: ...80 3 120 2 380 2 700 64 5 66 5 61 0 64 0 66 0 68 5 63 0 66 0 67 5 70 0 64 5 67 5 Starting Current A 1 4 1 3 2 1 1 9 2 8 2 6 15 5 20 25 Specifications may be subject to change without notice Specifications MK type MK 5010T E MK 5012T E Model Power Frequency Hz Three phase 50 60Hz 380 440 380V Input W Current A Air velocity Max m sec Air volume m3 h Noise dB Weight kg Width of unit cm 101 8 126 336 ...

Reviews: