![Mitsubishi Electric FR-S500 Series Instruction Manual Download Page 69](http://html.mh-extra.com/html/mitsubishi-electric/fr-s500-series/fr-s500-series_instruction-manual_1811897069.webp)
59
Function (Parameter) list
2
P
ara
me
te
r L
ist
O
u
tp
ut
te
rm
ina
l f
unc
tio
ns
41
Up-to-
frequency
sensitivity
0 to 100%
1%
10%
42
Output
frequency
detection
0 to 120Hz
0.1Hz
6Hz
43
Output
frequency
detection for
reverse
rotation
0 to 120Hz, - - -
0.1Hz
- - -
S
e
co
n
d fu
nc
tio
n
s
44
Second
acceleration/
deceleration
time
0 to 999s
0.1s
5s
45
Second
deceleration
time
0 to 999s, - - -
0.1s
- - -
46
Second
torque boost
0 to 15%, - - -
0.1%
- - -
47
Second V/F
(base
frequency)
0 to 120Hz, - - -
0.1Hz
- - -
C
ur
ren
t de
te
ct
io
n
48
Output current
detection level 0 to 200%
1%
150%
49
Output current
detection
signal delay
time
0 to 10s
0.1s
0s
50
Zero current
detection
level
0 to 200%
1%
5%
51
Zero current
detection
period
0.05 to 1s
0.01s
0.5s
Func-
tion
Para-
meter
Indica-
tion
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
Summary of Contents for FR-S500 Series