111
3
2)Remote register (For the details, refer to
.)
I/O signals when one station (FR-A5NC compatible) in the CC-Link Ver.1 is occupied. (
Pr. 544
= "0")
("n" indicates a value determined by the station number setting.)
The upper 8 bits are always H00 even if a value other than H00 is set.
I/O signals when one station in the CC-Link Ver.1 is occupied. (
Pr. 544
= "1")
("n" indicates a value determined by the station number setting.)
I/O signals when the double setting is set in the CC-Link Ver.2 (
Pr. 544
= "12")
("n" indicates a value determined by the station number setting. )
Device No.
Description
Device No.
Description
Upper 8 Bits
Lower 8 Bits
Upper 8 Bits
Lower 8 Bits
RWwn
Monitor code 2
Monitor code 1
RWrn
First monitor value
RWwn+1
Not used
RWrn+1
Second monitor value
RWwn+2
H00(arbitrary)
Instruction Code
RWrn+2
Reply code
RWwn+3
Write data
RWrn+3
Read data
Device No.
Description
Device No.
Description
Upper 8 Bits
Lower 8 Bits
Upper 8 Bits
Lower 8 Bits
RWwn
Monitor code 2
Monitor code 1
RWrn
First monitor value
RWwn+1
Not used
RWrn+1
Second monitor value
RWwn+2
Link parameter
extended setting
Instruction code
RWrn+2
Reply code
H00
RWwn+3
Write data
RWrn+3
Read data
Device No.
Description
Device No.
Description
Upper 8 Bits
Lower 8 Bits
Upper 8 Bits
Lower 8 Bits
RWwn
Monitor code 2
Monitor code 1
RWrn
First monitor value
RWwn+1
Not used
RWrn+1
Second monitor value
RWwn+2
Link parameter
extended setting
Instruction code
RWrn+2
Reply code
H00
RWwn+3
Write data
RWrn+3
Read data
RWwn+4
Monitor code 3
RWrn+4
Third monitor value
RWwn+5
Monitor code 4
RWrn+5
Fourth monitor value
RWwn+6
Monitor code 5
RWrn+6
Fifth monitor value
RWwn+7
Monitor code 6
RWrn+7
Sixth monitor value
HC2.book 111 ページ 2012年11月19日 月曜日 午前10時52分