12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
*11 The details of bits for the input terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
*12 The details of bits for the output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
*13 The details of bits for the option input terminal status 1 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX.) Every bit is 0
(OFF) when the option is not installed.
*14 The details of bits for the option input terminal status 2 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX. "—" denotes an
indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
*15 The details of bits for the option output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AY/A8AR. "—" denotes
an indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
*16 The increment varies depending on the
Pr.53
setting. (Refer to
*17 The monitored values are retained even if an inverter fault occurs. Resetting clears the retained values.
*18 Parameter setting is not valid to set the item as the main monitor item on the LCD operation panel (FR-LU08). Use the monitor function of the
FR-LU08 for the setting.
Monitor display for operation panel (Pr.52, Pr.774 to Pr.776)
• When
Pr.52
= "0" (initial value), the monitoring of output frequency, output current, output voltage and fault display can be
selected in sequence by pressing the SET key.
• The Load meter, motor excitation current and motor load factor are displayed on the second monitor (output current)
position, among the monitors set in
Pr.52
. Other monitors are displayed in the third monitor (output voltage) position.
• The monitor displayed at power ON is the first monitor (the output frequency monitor, according to the initial value). Display
the monitor you want to display on the first monitor and hold down the SET key for 1 second. To return to the output
frequency monitor, display the output frequency monitor and hold down the SET key for 1 second.
For example, when
Pr.52
= "20" (cumulative energization time), the monitor is displayed on the operation panel as shown
below.
b15
Standard model
b0
-
-
-
-
-
-
-
-
RES
MRS
RH
RM
RL
STR
STF
-
b15
Ethernet model
b0
-
-
-
-
-
-
-
-
-
-
-
-
-
DI1
DI0
-
b15
Safety communication model
b0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
b15
b0
-
-
-
-
-
-
-
FU
RUN
-
b15
b0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SO
SO
ABC
ABC
ABC
-
Standard model
Ethernet model
b15 Safety communication model
b0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
b15
b0
X11
X12
X13
X14
X10
X9
X8
X6
X7
X5
X4
X3
X2
X1
X0
X15
b15
b0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DY
-
b15
b0
-
-
-
-
-
RA3
RA2
Y6
RA1
Y5
Y4
Y3
Y2
Y1
Y0
-
Power-on monitor (first monitor)
Second monitor
Third monitor
Fault monitor
With fault
Output current monitor
Output voltage monitor
Output frequency monitor
• Power-on monitor (first monitor)
• Second monitor
• Third monitor
• Fault monitor
With fault
Output current monitor
Cumulative energization time monitor
Output frequency monitor
Summary of Contents for FR-E800
Page 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Page 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Page 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Page 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Page 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Page 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Page 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Page 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Page 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...