Parameter
Acceleration and deceleration
FR-D700 SC EC
6 - 59
6.6 Acceleration
and
deceleration
6.6.1
Acceleration and deceleration time (Pr. 7, Pr. 8, Pr. 20, Pr. 44, Pr. 45)
Used to set motor acceleration/deceleration time. Set a larger value for a slower speed increase/
decrease or a smaller value for a faster speed increase/decrease.
The above parameters can be set when Pr. 160 = 0.
Purpose
Parameters that must be set
Refer to
Section
Motor acceleration/deceleration time
setting
Acceleration/deceleration times
Pr. 7, Pr. 8,
Pr. 20, Pr. 44,
Pr. 45
Starting frequency
Starting frequency and start-time hold
Pr. 13, Pr. 571
Set acceleration/deceleration
pattern suitable for application
Acceleration/deceleration pattern
Pr. 29
Pr.
No.
Name
Initial Value
Setting
Range
Description
Parameters referred to
Refer to
Section
7
Acceleration
time
FR-D720S-008SC to
100SC,
FR-D740-080SC or less
5s
0–3600s
Set the motor acceleration
time.
3
10
29
125
126
178–182
Base frequency
DC injection brake
operation frequency
Acceleration/
deceleration pattern
selection
Frequency setting
gain frequency
Frequency setting
gain frequency
Input terminal func-
tion selection
FR-D740-120SC and
160SC
10s
8
Deceleration
time
FR-D720S-008SC to
100SC,
FR-D740-080SC or less
5s
0–3600s
Set the motor deceleration
time.
FR-D740-120SC and
160SC
10s
20
Acceleration/
deceleration
reference
frequency
50Hz
1–400Hz
Set the frequency that will be
the basis of acceleration/decel-
eration time.
As acceleration/deceleration
time, set the frequency change
time from stop to Pr. 20.
44
Second accel-
eration/decel-
eration time
FR-D720S-008SC to
100SC,
FR-D740-080SC or less
5s
0–3600s
Set the acceleration/decelera-
tion time when the RT signal is
on.
FR-D740-120SC and
160SC
10s
45
Second decel-
eration time
9999
0–3600s
Set the deceleration time when
the RT signal is on.
9999
Acceleration time = decelera-
tion time
Summary of Contents for FR-D720S SC EC
Page 2: ......
Page 4: ......
Page 24: ...Description of the case Product checking and part identification 1 4 ...
Page 108: ...Operation panel Operation 4 20 ...
Page 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Page 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Page 504: ...Specification change Appendix A 20 ...
Page 505: ......
Page 506: ......
Page 510: ...Index Appendix A 24 ...
Page 511: ......