VECTOR CONTROL
31
6
6.4 Offline auto tuning
• The offline auto tuning enables the optimal operation of a motor with resolver.
POINT
POINT
• Refer to the Instruction Manual (Detailed) of the inverter to perform the offline auto tuning.
• This section explains the specific information of the motor with a resolver.
Pr.
Name
Initial
value
Setting
range
Description
PM motor
Induction motor
96
C110
Auto tuning setting/status
0
0
No offline auto tuning
1
Performs offline auto tuning (without motor rotation)
11
Performs offline auto tuning only for motor constant R1 (without
motor rotation)
101
Performs resolver position tuning
and offline auto tuning
(with motor slight rotation)
Performs offline auto tuning
(with motor rotation)
463
C210
Second motor auto tuning setting/status 0
0, 1, 11, 101
Performs offline auto tuning for the second motor (Refer to
Pr.96
for
the setting.)
Vector
Vector
Vector