![Mitsubishi Electric FR-A720-55K Instruction Manual Download Page 42](http://html.mh-extra.com/html/mitsubishi-electric/fr-a720-55k/fr-a720-55k_instruction-manual_239754042.webp)
37
MOTOR THERMISTOR INTERFACE
6
6.3.5 Motor temperature detection signal
When motor temperature exceeds the detection level, motor temperature detection signal (Y55) is output.
(Set
Pr. 407 Motor temperature detection filter
≠
"9999")
Set "55 (positive logic)" or "155 (negative logic)" in the following parameters to output the motor
temperature detection signal (Y55) when motor temperature exceeds the detection level.
⋅
Pr.190 to Pr.196 Output terminal function selection
(Refer to
the Instruction Manual of the inverter
for details.)
⋅
Pr.313 to Pr.319 DO0 to DO6 output function selections
(Refer to
the Instruction Manual of FR-A7AY
for details.)
⋅
Pr.320 to Pr.322 RA1 to RA3 output function selections
(Refer to
the Instruction Manual of FR-A7AR
for details.)
Use the following parameter to adjust the temperature to output the motor temperature detection signal
(Y55).
* Read/write is enabled when using FR-A7AZ.
Parameter Number
Name
Initial Value
Minimum setting
increments
Setting Range
750 *
Motor temperature detection level
75
°
C
1
°
C
0 to 200
°
C
REMARKS
⋅
The motor temperature detection signal is not available when
Pr. 407
= "9999".
Pr. 750
Motor temperature
Time
Y55
OFF
ON
OFF
Hysteresis range (5 C)
Y55 signal turns OFF when motor temperature
become
Pr. 750